[Archive] Using a Modem for J-Series, SRX console for out-of-band management.

0

0

Article ID: KB12507 KB Last Updated: 06 Oct 2020Version: 6.0
Summary:
Using a Modem for J-Series, SRX console for out-of-band management.
Symptoms:
• Configure a US Robotics Sportster modem to the console port
• Remote dial up access to the J-Series, SRX console
• Obtain console message via out of band connection using dial up modem
 
Solution:
The Console port of J-Series and SRX routers is a RJ-45 serial console port connector, for VT100 terminal emulator programs to perform local configuration and administration. Use a RJ45-DB25 cable between the router and US Robotics Sportster modem.
  1. Connect the router console to the modem with a RJ45-DB25 cable. The following cable pinout was used to connect successfully with the console port on a router to a US Robotics Sportster 56K modem.

    RJ-45  DB25 (Plug)   
    NC     8   
    6      2   
    3      3   
    7      20   
    4      7   
    2      6   
    8      4   
    1      5   
    NC     22
  2. Set the DIP switches on the USR like the following:

    1 - DTR normal (down)
    2 - Verbal result codes (up)
    3 - Suppress result codes (up)
    4 - No echo, offline commands (down)
    5 - Auto answer on (up)
    6 - Carrier detect override (up)
    7 - Load NVRAM defaults (up)
    8 - Dumb mode (up)
    
  3. Set the following AT commands on the modem console:

    at&U6 (minimum link rate-9600 bps)
    at&N6 (set the maximum speed to 9600bps, the Router can only talk 9600bps)
    at&W0 (store configuration 0) 

    For other brands of modems, please consult the vendor for more information on customizing the modem to communicate at 9600 bps, 8 bit, no parity, 1 stop bit.

Modification History:
[Archive] : 2020-10-03 : Sam :  EOL Devices .  Can be archived .
Comment on this article > Affected Products Browse the Knowledge Base for more articles related to these product categories. Select a category to begin.

Getting Up and Running with Junos

Getting Up and Running with Junos Security Alerts and Vulnerabilities Product Alerts and Software Release Notices Problem Report (PR) Search Tool EOL Notices and Bulletins JTAC User Guide Customer Care User Guide Pathfinder SRX High Availability Configurator SRX VPN Configurator Training Courses and Videos End User Licence Agreement Global Search