Device Boot failure after install of IDP blade in ISG-1000/ISG-2000

0

0

Article ID: KB12689 KB Last Updated: 17 Jun 2010Version: 2.0
Summary:
After installing IDP blade in an ISG device the boot process of the firewall stops with the error:
“CPU board Rev-E cannot be used as Management board!!!: Force system stop!!!””
Symptoms:
Unable to successfully boot an ISG firewall with a recently installed IDP security module due to the error “CPU board Rev-E cannot be used as Management board!!!: Force system stop!!!””

This error is an indication that an IDP security module may have been installed into an incorrect slot causing the device to try to use the security module as the management module.
Solution:
The IDP security module boards must be installed in specific slots in the ISG. The slot order for the ISG are as follows, with the slot numbers being numbered from lowest to highest from the front of the device to the back of the device.

When inserting the IDP Security module, place it in the slot in closest to the backup of the device first.  
For example: If using one security module, install it into Slot 3, and if using two security modules use Slots 3 and 2.

ISG-1000
Slot 1 (closest to the front of the device) - Asic Module
Slot 2 - IDP Security Module
Slot 3 - IDP Security Module
Slot 4 (closest to the rear of the device)- Management Module

ISG-2000
Slot 0 (closest to the front of the device) - Asic Module
Slot 1 - IDP Security Module
Slot 2 - IDP Security Module
Slot 3 - IDP Security Module
Slot 4 (closest to the rear of the device)- Management Module


If further information is needed on the installation of the IDP security module, refer to the Upgrade Guides:

ISG-1000
http://www.juniper.net/techpubs/hardware/netscreen-systems/netscreen-systems50/isg1000_up_revB.pdf

ISG-2000
http://www.juniper.net/techpubs/hardware/netscreen-systems/netscreen-systems50/isg2000_up_revc.pdf
Comment on this article > Affected Products Browse the Knowledge Base for more articles related to these product categories. Select a category to begin.

Getting Up and Running with Junos

Getting Up and Running with Junos Security Alerts and Vulnerabilities Product Alerts and Software Release Notices Problem Report (PR) Search Tool EOL Notices and Bulletins JTAC User Guide Customer Care User Guide Pathfinder SRX High Availability Configurator SRX VPN Configurator Training Courses and Videos End User Licence Agreement Global Search