Control ports for Chassis Cluster configuration on SRX1400

0

0

Article ID: KB20916 KB Last Updated: 08 Sep 2014Version: 3.0
Summary:
This article provides information on how to implement a chassis cluster on the SRX1400 device.
Symptoms:
From Junos 11.1, High Availability is supported on SRX1400. This is different from the SRX3000 device, which has dedicated control port for the ge-0/0/10 and ge-0/0/11 control links that will be used as control ports, when the Chassis Cluster is enabled.

The physical link status of the control ports is down, but the ports are connected back to back. Why are they down?
Cause:

Solution:
The Chassis Cluster control port 0 and port 1 can only be ge-0/0/10 and ge-0/0/11, when the Chassis Cluster is enabled on a SRX1400 device.


NOTE: When you use ge-0/0/11 as a control port, you must use a fiber SFP transceiver, but you can use copper or fiber SFP transceiver on ge-0/0/10.


The other configuration instructions can be found in the TN10 Tech Note for high-end SRX devices. For more information, refer to KB15650 - SRX Getting Started - Configure Chassis Cluster (High Availability).

Configuration for the Chassis Cluster:
{primary:node0}[edit]
root@srx1400-1# show chassis cluster
reth-count 2;
redundancy-group 0 {
        node 0 priority 200;
        node 1 priority 100;
}
redundancy-group 1 {
        node 0 priority 200;
        node 1 priority 100;
}
The special configuration is no longer required:
{primary:node0}[edit]
root@SRX1400-1# run show chassis cluster information
node0:
--------------------------------------------------------------------------
Redundancy mode:
         Configured mode: active-active
         Operational mode: active-active
Control link statistics:
         Control link 0:
                 Heartbeat packets sent: 73138
                 Heartbeat packets received: 5905
                 Heartbeat packet errors: 0
                 Duplicate heartbeat packets received: 5685
         Control link 1:
                 Heartbeat packets sent: 73138
                 Heartbeat packets received: 9955
                 Heartbeat packet errors: 0
                 Duplicate heartbeat packets received: 93
         Control recovery packet count: 0
         Sequence number of last heartbeat packet sent: 73135
         Sequence number of last heartbeat packet received: 5732
Fabric link statistics:
         Probes sent: 73135
         Probes received: 6945
         Probe errors: 0
         Probes not processed: 6692
         Probes dropped due to control link down: 0
         Probes dropped due to fabric link down: 0
         Sequence number of last probe sent: 73135
         Sequence number of last probe received: 5732
Chassis cluster LED information:
         Current LED color: Green
         Last LED change reason: No failures

Important: 'ge-0/0/10' and 'ge-0/0/11' will be physical link down, when the chassis cluster is enabled; even when directly connected back to back.

To check the control links status, issue the show chassis cluster interfaces command. If either link is up, the control link status will be up. So, to check if both the control links are up, issue the show chassis cluster information command to check if both of the control links send and receive heartbeats.
{primary:node0}
root@SRX1400-a> show chassis cluster interfaces
Control link 0 name: em0
Control link 1 name: em1
Control link status: Up

Fabric interfaces:
Name Child-interface Status
fab0 ge-0/0/2 up
fab0
fab1 ge-4/0/2 up
fab1
Fabric link status: Up

Related Links

Comment on this article > Affected Products Browse the Knowledge Base for more articles related to these product categories. Select a category to begin.

Getting Up and Running with Junos

Getting Up and Running with Junos Security Alerts and Vulnerabilities Product Alerts and Software Release Notices Problem Report (PR) Search Tool EOL Notices and Bulletins JTAC User Guide Customer Care User Guide Pathfinder SRX High Availability Configurator SRX VPN Configurator Training Courses and Videos End User Licence Agreement Global Search