This article provides information on how to check the status of the HA LED on SRX platforms.
Starting with 1.x releases, the
show chassis craft-interface command will show the status of HA LED on all SRX platforms; except for SRX5000.
SRX3600> show chassis craft-interface
node0:
-------------------------------------------------------------
Front Panel System LEDs:
Routing Engine 0 1
--------------------------
OK * .
Fail . .
Master * .
Front Panel Alarm Indicators:
-----------------------------
Red LED .
Yellow LED .
Front Panel FPC LEDs:
FPC 0 1 2 3 4 5 6 7 8 9 10 11 12
-----------------------------------------------------------
Red . . . . . . . . . . . . .
Green * * * * * . . . * * * * .
CB LEDs:
CB 0 1
-------------
OK * .
Fail . .
Master * .
PS LEDs:
PS 0 1 2 3
--------------------
Red . . . .
Green * * . .
Fan Tray LEDs:
FT 0
--------
Red .
Green *
HA LED: < Notice here
--------
Red .
Green *
Amber .
SFB LED:
SFB 0
--------
Red .
Green *
Amber .
Blink .
CFM Ok/Fail LED:
--------
Red .
Green *
Amber .
CFM Service LED:
--------
Red .
Green *
Amber .
For the SRX5000 platform, this command will not work, as the HA LED is part of the SPC card and not the RE.
Prior to 11.x releases, the output of
chassis cluster information was bundled together in one big output, which included the status of the LED as well. Type the following to check the status of the HA LED:
{primary:node0}[edit]
SRX# run show chassis cluster information | match "Current LED color"
Current LED color: Green
Current LED color: Green
Starting with 11.x releases, the output of
chassis cluster information is subdivided into many categories:
{primary:node0}[edit]
root@D10_30-SRX240H-Node0-HQ# run show chassis cluster information ?
Possible completions:
<[Enter]> Execute this command
coldsync Display coldsync information
command-history Display command history
control-link Display control link information
detail Display all chassis cluster information < This is the one you need to use.
fabric-link Display fabric link information
hardware-monitor Display hardware monitoring information
interface-monitor Display interface monitoring information
issu Display ISSU information
redundancy-group Display chassis cluster status per redundancy-group (0..24)
spu Display SPU information
| Pipe through a command
{primary:node0}[edit]
root@D10_30-SRX240H-Node0-HQ# run show chassis cluster information detail | match "Current LED color"
Current LED color: Green
Current LED color: Green