[MX] Supportable egress-shaping-overhead range for MPC.

0

0

Article ID: KB31160 KB Last Updated: 07 Oct 2016Version: 1.0
Summary:

This article defines supportable egress-shaping-overhead range for MPC. The configurable egress-shaping-overhead range defined in Juniper's technical documentation may be out of bound for MPC.

Solution:

Juniper's technical documentation on egress-shaping-overhead defines configurable shaping-overhead between -63 and 192. The supported ranges for MCP is presented below.

MPC's egress-shaping-overhead is designed to work with these values.

traffic-control-profiles shaping

MPC supportable range : -62 through 56

Example config 1
---------------------------------------------------------------------------------------------------------------------------------------------------------
set chassis fpc X pic X traffic-manager egress-shaping-overhead XX

set class-of-service traffic-control-profiles TEST1 shaping-rate 100m
set class-of-service traffic-control-profiles TEST1 shaping-rate burst-size 1
set class-of-service interfaces ge-x/x/x output-traffic-control-profile TEST1

---------------------------------------------------------------------------------------------------------------------------------------------------------
interface shaping

MPC supportable range : -62 through 56

Example config 2
---------------------------------------------------------------------------------------------------------------------------------------------------------
set chassis fpc X pic X traffic-manager egress-shaping-overhead XX

set class-of-service interfaces ge-x/x/x shaping-rate 100m

---------------------------------------------------------------------------------------------------------------------------------------------------------
unit shaping

MPC supportable range : -62 through 120

Example config 3
---------------------------------------------------------------------------------------------------------------------------------------------------------
set chassis fpc X pic X traffic-manager egress-shaping-overhead XX

set class-of-service interfaces ge-x/x/x unit x shaping-rate 100m

---------------------------------------------------------------------------------------------------------------------------------------------------------
Comment on this article > Affected Products Browse the Knowledge Base for more articles related to these product categories. Select a category to begin.

Getting Up and Running with Junos

Getting Up and Running with Junos Security Alerts and Vulnerabilities Product Alerts and Software Release Notices Problem Report (PR) Search Tool EOL Notices and Bulletins JTAC User Guide Customer Care User Guide Pathfinder SRX High Availability Configurator SRX VPN Configurator Training Courses and Videos End User Licence Agreement Global Search