TOE chip memory errors reported on routers with MPC-3D-16XGE-SFPP FPCs

0

0

Article ID: KB31235 KB Last Updated: 14 Feb 2017Version: 2.0
Summary:

This article explains the possible reasons and resolution for TOE chip memory errors reported on routers with MPC-3D-16XGE-SFPP and MPC-3D-16XGE-SFPP-R-B FPCs.

Symptoms:

Syslog reports the following FPC major errors and a TOE wedge:

Nov 10 06:56:41 MX2020-lab fpc0 TFTP (block) write - saw ack 47, expected 48
Nov 10 06:56:41 MX2020-lab fpc0 TOE:TOE XM.1.1.0 : SetErr - thread 0 ifetch err
Nov 10 06:56:41 MX2020-lab alarmd[9975]: Alarm set: FPC color=RED, class=CHASSIS, reason=FPC 0 Major Errors
Nov 10 06:56:41 MX2020-lab craftd[8979]: Major alarm set, FPC 0 Major Errors
Nov 10 06:56:42 MX2020-lab fpc0 Error (0x10402), module: TOE, type:
Nov 10 06:56:42 MX2020-lab fpc0 TFTP read - error code 1 (File not found)
Nov 10 06:56:53 MX2020-lab fpc0 TFTP (block) write - saw ack 47, expected 48
Nov 10 06:56:53 MX2020-lab fpc0 TOE:TOE XM.1.1.0 : SetErr - XM TOE chip 20 Memory Error Thread 0, INSTR Addr 0x1f7c
Nov 10 06:56:54 MX2020-lab fpc0 Error (0x70190), module: XMCHIP(3), type:
Nov 10 06:57:05 MX2020-lab fpc0 XMCHIP(3):XMCHIP(3): HOSTIF: Protect: Parity error for SRAM in bank 0

Nov 10 06:57:17 MX2020-lab fpc0 TOE:TOE XM.1.1.0 : SetErr - ** WEDGE DETECTED IN PFE 1 stream 0 TOE host packet transfer: reason code 0x1
Nov 10 06:57:18 MX2020-lab fpc0 Error (0x10407), module: TOE, type:

Nov 10 06:57:30 MX2020-lab fpc0 TOE:TOE XM.1.1.0 : SetErr - ** WEDGE DETECTED IN PFE 1 stream 1 TOE host packet transfer: reason code 0x1
Nov 10 06:57:30 MX2020-lab fpc0 Error (0x10407), module: TOE, type:
Nov 10 06:57:30 MX2020-lab fpc0 TFTP read - error code 1 (File not found)

Cause:

These messages could indicate a hardware issue or a transient memory issue.

Solution:
If reported, reboot the FPC and monitor. If the errors return, open a case with JTAC to investigate further. 

Comment on this article > Affected Products Browse the Knowledge Base for more articles related to these product categories. Select a category to begin.

Getting Up and Running with Junos

Getting Up and Running with Junos Security Alerts and Vulnerabilities Product Alerts and Software Release Notices Problem Report (PR) Search Tool EOL Notices and Bulletins JTAC User Guide Customer Care User Guide Pathfinder SRX High Availability Configurator SRX VPN Configurator Training Courses and Videos End User Licence Agreement Global Search