Support Support Downloads Knowledge Base Juniper Support Portal Community

Knowledge Base

Search our Knowledge Base sites to find answers to your questions.

Ask All Knowledge Base Sites All Knowledge Base Sites JunosE Defect (KA)Knowledge BaseSecurity AdvisoriesTechnical BulletinsTechnotes Sign in to display secure content and recently viewed articles

[Junos] 'show interface diagnostics optics' for CFP-100G-SR10 displays zero output/receiver power

0

0

Article ID: KB31503 KB Last Updated: 30 Mar 2017Version: 2.0
Summary:

Due to a hardware limitation for the CFP-100G-SR10, the output of 'show interface diagnostics optics' on a 100G interface with CFP-100G-SR10 CFP returns 0.000 output/receiver power.

Symptoms:

When running the 'show interface diagnostics optics' command on a 100G interface which has CFP-100G-SR10 CFP installed, the output power is shown as "0.000":

lab@router> show interfaces diagnostics optics et-5/1/0 
Physical interface: et-5/1/0
    Module
temperature                        :  39 degrees C / 102 degrees F
    Module
voltage                            :  3.2710 V
    Module temperature high
alarm             :  Off
    Module temperature low
alarm              :  Off
    Module temperature high
warning           :  Off
    Module temperature low
warning            :  Off
    Module voltage high
alarm                 :  Off
    Module voltage low
alarm                  :  Off
    Module voltage high
warning               :  Off
    Module voltage low
warning                :  Off
   
Module not ready alarm                    :  Off
    Module low power
alarm                    :  Off
    Module initialization incomplete
alarm    :  Off
    Module fault
alarm                        :  Off
    PLD Flash initialization fault alarm      :  Off
    Power supply fault alarm                  :  Off
    Checksum fault alarm                      :  Off
    Tx laser disabled alarm                   :  Off
    Tx loss of signal functionality alarm     :  Off
    Tx CDR loss of lock alarm                 :  Off
    Rx loss of signal alarm                   :  Off
    Rx CDR loss of lock alarm                 :  Off
    Module temperature high alarm threshold   :  74 degrees C / 165 degrees F
    Module temperature low alarm threshold    :  -4 degrees C / 25 degrees F
    Module temperature high warning threshold :  70 degrees C / 158 degrees F
    Module temperature low warning threshold  :  0 degrees C / 32 degrees F
    Module voltage high alarm threshold       :  3.6640 V
    Module voltage low alarm threshold        :  2.9340 V
    Module voltage high warning threshold     :  3.4640 V
    Module voltage low warning threshold      :  3.1340 V
    Laser bias current high alarm threshold   :  15.000 mA
    Laser bias current low alarm threshold    :  4.000 mA
    Laser bias current high warning threshold :  14.000 mA
    Laser bias current low warning threshold  :  5.000 mA
    Laser output power high alarm threshold   :  0.0000 mW / - Inf dBm
    Laser output power low alarm threshold    :  0.0000 mW / - Inf dBm
    Laser output power high warning threshold :  0.0000 mW / - Inf dBm
    Laser output power low warning threshold  :  0.0000 mW / - Inf dBm
    Laser
rx power high alarm threshold       :  0.0000 mW / - Inf dBm
    Laser
rx power low alarm threshold        :  0.0000 mW / - Inf dBm
    Laser
rx power high warning threshold     :  0.0000 mW / - Inf dBm
    Laser rx power low warning threshold      :  0.0000 mW / - Inf dBm
    Laser temperature high alarm threshold    :  74 degrees C / 165 degrees F
    Laser temperature low alarm threshold     :  -4 degrees C / 25 degrees F
    Laser temperature high warning threshold  :  70 degrees C / 158 degrees F
    Laser temperature low warning threshold   :  0 degrees C / 32 degrees F
  Lane 0                                
    Laser bias current                        :  10.184 mA

    Laser output power                        :  0.000  <--- showing zero

    Laser temperature                         :  0 degrees C / 32 degrees F
    Laser receiver power                      :  0.000  <--- showing zero
    Laser bias current high alarm             :  Off
    Laser bias current low alarm              :  Off
    Laser bias current high warning           :  Off
    Laser bias current low warning            :  Off
    Laser output power high alarm             :  Off
    Laser output power low alarm              :  Off
    Laser output power high warning           :  Off
    Laser output power low warning            :  Off
    Laser temperature high alarm              :  Off
    Laser temperature low alarm               :  Off
    Laser temperature high warning            :  Off
    Laser temperature low warning             :  Off
    Laser receiver power high alarm           :  Off
    Laser receiver power low alarm            :  Off
    Laser receiver power high warning         :  Off
    Laser receiver power low warning          :  Off
    Tx loss of signal functionality alarm     :  Off
    Tx CDR loss of lock alarm                 :  Off
    Rx loss of signal alarm                   :  Off
    Rx CDR loss of lock alarm                 :  Off
    APD supply fault alarm                    :  Off
    TEC fault alarm                           :  Off
    Wavelength unlocked alarm                 :  Off
  Lane 1
    Laser bias current                        :  10.184 mA

    Laser output
power                        :  0.000  <--- showing zero

    Laser temperature                         :  0 degrees C / 32 degrees F
    Laser receiver
power                      :  0.000  <--- showing zero
    Laser bias current high
alarm             :  Off
    Laser bias current low
alarm              :  Off
    Laser bias current high
warning           :  Off
    Laser bias current low
warning            :  Off
    Laser output power high
alarm             :  Off
    Laser output power low
alarm              :  Off
    Laser output power high
warning           :  Off
    Laser output power low
warning            :  Off
    Laser temperature high
alarm              :  Off
    Laser temperature low
alarm               :  Off
    Laser temperature high
warning            :  Off
    Laser temperature low
warning             :  Off
    Laser receiver power high
alarm           :  Off
    Laser receiver power low
alarm            :  Off
    Laser receiver power high
warning         :  Off
    Laser receiver power low
warning          :  Off
    Tx loss of signal functionality alarm     :  Off
    Tx CDR loss of lock alarm                 :  Off
    Rx loss of signal alarm                   :  Off
    Rx CDR loss of lock alarm                 :  Off
    APD supply fault alarm                    :  Off
    TEC fault alarm                           :  Off
    Wavelength unlocked alarm                 :  Off
  Lane 2
    Laser bias current                        :  10.184 mA

    Laser output
power                        :  0.000  <--- showing zero

    Laser temperature                         :  0 degrees C / 32 degrees F
    Laser receiver
power                      :  0.000  <--- showing zero
    Laser bias current high
alarm             :  Off
    Laser bias current low
alarm              :  Off
    Laser bias current high
warning           :  Off
    Laser bias current low
warning            :  Off
    Laser output power high
alarm             :  Off
    Laser output power low
alarm              :  Off
    Laser output power high
warning           :  Off
    Laser output power low
warning            :  Off
    Laser temperature high
alarm              :  Off
    Laser temperature low
alarm               :  Off
    Laser temperature high
warning            :  Off
    Laser temperature low
warning             :  Off
    Laser receiver power high
alarm           :  Off
    Laser receiver power low
alarm            :  Off
    Laser receiver power high
warning         :  Off
    Laser receiver power low
warning          :  Off
    Tx loss of signal functionality alarm     :  Off
    Tx CDR loss of lock alarm                 :  Off
    Rx loss of signal alarm                   :  Off
    Rx CDR loss of lock alarm                 :  Off
    APD supply fault
alarm                    :  Off
    TEC fault
alarm                           :  Off
    Wavelength unlocked
alarm                 :  Off
  Lane 3
    Laser bias
current                        :  10.184 mA

    Laser output
power                        :  0.000  <--- showing zero

    Laser temperature                         :  0 degrees C / 32 degrees F
    Laser receiver
power                      :  0.000  <--- showing zero
    Laser bias current high
alarm             :  Off
    Laser bias current low
alarm              :  Off
    Laser bias current high
warning           :  Off
    Laser bias current low
warning            :  Off
    Laser output power high
alarm             :  Off
    Laser output power low
alarm              :  Off
    Laser output power high
warning           :  Off
    Laser output power low
warning            :  Off
    Laser temperature high
alarm              :  Off
    Laser temperature low
alarm               :  Off
    Laser temperature high
warning            :  Off
    Laser temperature low
warning             :  Off
    Laser receiver power high
alarm           :  Off
    Laser receiver power low
alarm            :  Off
    Laser receiver power high
warning         :  Off
    Laser receiver power low
warning          :  Off
    Tx loss of signal functionality alarm     :  Off
    Tx CDR loss of lock alarm                 :  Off
    Rx loss of signal alarm                   :  Off
    Rx CDR loss of lock alarm                 :  Off
    APD supply fault alarm                    :  Off
    TEC fault alarm                           :  Off
    Wavelength unlocked alarm                 :  Off
  Lane 4
    Laser bias current                        :  10.184 mA

    Laser output power                        :  0.000  <--- showing zero

    Laser temperature                         :  0 degrees C / 32 degrees F
    Laser receiver power                      :  0.000  <--- showing zero
    Laser bias current high alarm             :  Off
    Laser bias current low alarm              :  Off
    Laser bias current high warning           :  Off
    Laser bias current low warning            :  Off
    Laser output power high alarm             :  Off
    Laser output power low alarm              :  Off
    Laser output power high warning           :  Off
    Laser output power low warning            :  Off
    Laser temperature high alarm              :  Off
    Laser temperature low alarm               :  Off
    Laser temperature high warning            :  Off
    Laser temperature low warning             :  Off
    Laser receiver power high alarm           :  Off
    Laser receiver power low alarm            :  Off
    Laser receiver power high warning         :  Off
    Laser receiver power low warning          :  Off
    Tx loss of signal functionality alarm     :  Off
    Tx CDR loss of lock alarm                 :  Off
    Rx loss of signal alarm                   :  Off
    Rx CDR loss of lock alarm                 :  Off
    APD supply fault
alarm                    :  Off
    TEC fault
alarm                           :  Off
    Wavelength unlocked
alarm                 :  Off
 <snipped>
Solution:

The CFP-100GBASE-SR10 (740-035329) / Finisar /FTLC8281RCNM-J3 is working as designed. This is a hardware limitation for the CFP-100G-SR10.

The CFP does not support DDM (Digital Diagnostic Monitoring), so the laser output/receiver values shown will always be zero.

Comment on this article > Affected Products Browse the Knowledge Base for more articles related to these product categories. Select a category to begin.

Getting Up and Running with Junos

Getting Up and Running with Junos Security Alerts and Vulnerabilities Product Alerts and Software Release Notices Problem Report (PR) Search Tool EOL Notices and Bulletins JTAC User Guide Customer Care User Guide Pathfinder SRX High Availability Configurator SRX VPN Configurator Training Courses and Videos End User Licence Agreement Global Search