Support Support Downloads Knowledge Base Juniper Support Portal Community

Knowledge Base

Search our Knowledge Base sites to find answers to your questions.

Ask All Knowledge Base Sites All Knowledge Base Sites JunosE Defect (KA)Knowledge BaseSecurity AdvisoriesTechnical BulletinsTechnotes Sign in to display secure content and recently viewed articles

Syslog message: XMCHIP.*Scheduler.*Protect.*Parity error for TDM table single port SRAM

0

0

Article ID: KB31601 KB Last Updated: 07 Oct 2021Version: 3.0
Summary:

The "Parity error for TDM table single port SRAM" message reports a transient hardware error.

This is a Troubleshooting Article for a PFE ASIC Syslog Event.
To view other documented syslog events related to XMCHIP, XLCHIP, MQCHIP, LUCHIP, EACHIP, and PECHIP, see KB31893 - Index of Articles for Troubleshooting PFE ASIC Syslog Events.

.

Symptoms:

When a "Parity error for TDM table single port SRAM" event occurs, a message similar to the following is reported:

Nov 2 06:45:01 router0 : %PFE-3: fpc13 XMCHIP(1):XMCHIP(1): Scheduler: Protect: Parity error for TDM table single port SRAM (1)

Indications:

  • Service Impact:  No permanent impact of packet forwarding
  • Alarm will be raised.
  • Service Impact: If the address entry is high above 500 then there is no operational impact 

 

Cause:

This is due to a transient parity error detected in SRAM memory on the XMCHIP.

Solution:

PR1185074 will automatically correct this condition. 

Perform these steps to determine the cause and resolve the problem (if any).  Continue through each step until the problem is resolved.

  1. Collect the show command output.

    Capture the output to a file (in case you have to open a technical support case). To do this, configure each SSH client/terminal emulator to log your session.

    show log messages
    show log chassisd
    start shell network pfe <fpc#>
    show nvram
    show syslog messages
    exit

  2. Analyze the show command output.

    In the 'show log messages', review the events that occurred at or just before the appearance of the "Parity error for TDM table single port SRAM" message. Frequently these events help identify the cause.

  • No RMA required.

  • Restart class-of-service soft during Maintenance Window should clear this error.

  • FPC restart during Maintenance Window should clear this error.

  • With the single occurrence, the alarm can be cleared using command:

    • clear chassis fpc errors fpc-slot <x> all

    • Note: This command is available in Junos OS 16.1R4-S2, 16.1R5, 16.2R2, 17.1R2, and 17.2R1 or higher.

  • The multiple continuous occurrences of errors require FPC restart during Maintenance Window to clear the alarms.

  • Contact your technical support representative if the issue is seen after a FPC restart.

This article is indexed in KB31893 - Primary Index of Articles for Troubleshooting PFE ASIC Syslog Events; tag XMCHIPTSG

Tip: When looking at an event in the logs, it is important to focus on the first error message in a collection of syslog messages. The first error message is usually the cause of all the follow-on error messages. The follow-on collateral damage error messages can be ignored.

Modification History:
2019-10-14: Article reviewed for accuracy; no changes required.
Comment on this article > Affected Products Browse the Knowledge Base for more articles related to these product categories. Select a category to begin.

Getting Up and Running with Junos

Getting Up and Running with Junos Security Alerts and Vulnerabilities Product Alerts and Software Release Notices Problem Report (PR) Search Tool EOL Notices and Bulletins JTAC User Guide Customer Care User Guide Pathfinder SRX High Availability Configurator SRX VPN Configurator Training Courses and Videos End User Licence Agreement Global Search