[QFX5100] MC-LAG may fail to work after upgrading from Junos OS 14.1X53 to 17.1R1

0

0

Article ID: KB31882 KB Last Updated: 30 Mar 2018Version: 1.0
Summary:

On QFX5100, MC-LAG may fail to work after upgrading from Junos OS 14.1X53 to 17.1R1. When this issue happens, it is likely due to the reason that the "redundancy-group-id-list" option is not configured under the "protocols iccp peer" hierarchy.

Symptoms:

After the upgrade, ICCP peers fail to be established with the status below:

{master:0}
root@LEAF1> show iccp
 
Redundancy Group Information for peer 192.168.100.1
  TCP Connection       : In progress   <<<<<<<<<<<<<<<
  Liveliness Detection : Down
Backup liveness peer status: Down
Client Application: lacpd
Client Application: l2ald_iccpd_client
Cause:

On QFX5100 with Junos OS 14.1X53, redundancy-group-id-list is an optional and hidden command, whereas with Junos OS 17.1R1, it is a mandatory command which needs to be added properly.
 

Solution:
If similar issue occurs after upgrading to Junos OS 17.1R1, try to add "redundancy-group-id-list" option on both mc-lag peers with the following commands.

Example:

{master:0}[edit]
user@LEAF0# set protocols iccp peer 192.168.100.2 redundancy-group-id-list 1

{master:0}[edit]
user@LEAF2# set protocols iccp peer 192.168.100.1 redundancy-group-id-list 1


Or before the upgrade, add the above commands proactively.

Note: On Junos OS 14.1X53, "redundancy-group-id-list" is a hidden command, so input the entire completely. You may see a warning like below after adding such command on Junos OS 14.1X53 which is expected and does not affect the functionality or upgrade.

root@LEAF2# show protocols iccp
local-ip-addr 192.168.100.1;
peer 192.168.100.2 {
    session-establishment-hold-time 100;
    ##
    ## Warning: value redundancy-group-id-list ignored: unsupported platform (qfx5100-48s-6q)
    ##
    redundancy-group-id-list 1;
    backup-liveness-detection {
        backup-peer-ip 172.27.113.75;
    }
    liveness-detection {
        minimum-interval 1000;
        multiplier 3;
    }
}
  • redundancy-group-id-list was also a hidden open on the initial code for QFX10K, but a commit check did not allow the commit through.
  • "redundancy-group-id-list" :  only supports one, i.e. redundancy-group-id-list [ x ]. Multiple redundancy ids are not supported, i.e., redundancy-group-id-list [ x  y]. There are commit checks in the newer Junos OS codes. However, in the older code, there is not a commit check.
Comment on this article > Affected Products Browse the Knowledge Base for more articles related to these product categories. Select a category to begin.

Getting Up and Running with Junos

Getting Up and Running with Junos Security Alerts and Vulnerabilities Product Alerts and Software Release Notices Problem Report (PR) Search Tool EOL Notices and Bulletins JTAC User Guide Customer Care User Guide Pathfinder SRX High Availability Configurator SRX VPN Configurator Training Courses and Videos End User Licence Agreement Global Search