Ask All Knowledge Base Sites All Knowledge Base Sites JunosE Defect (KA)Knowledge BaseSecurity AdvisoriesTechnical BulletinsTechnotes Sign in to display secure content and recently viewed articles

FPC reconnects when graceful RE switchover is performed

0

0

Article ID: KB33269 KB Last Updated: 02 Nov 2018Version: 1.0
Summary:

This article discusses how FPCs reconnect when a graceful RE switch over is performed on an M120 device.

Symptoms:

In a dual RE scenario when RE switchover occurs either gracefully or ungracefully, the following may be observed:

Consider an M120 device with dual REs and empty FPC slots:

lab@M120-R1# run show chassis routing-engine | no-more
Oct 19 10:59:59
Routing Engine status:
  Slot 0:
    Current state                  Backup
    Election priority              Master (default)
    Temperature                 44 degrees C / 111 degrees F
    CPU temperature             45 degrees C / 113 degrees F
    DRAM                      2048 MB (2048 MB installed)
    Memory utilization          24 percent
    CPU utilization:
      User                       0 percent
      Background                 0 percent
      Kernel                     1 percent
      Interrupt                  0 percent
      Idle                      99 percent
    Model                          RE-A-2000
    Serial ID                      1000737665
    Start time                     2018-10-15 10:49:34 IST
    Uptime                         4 days, 10 minutes, 7 seconds
    Last reboot reason             0x11:power cycle/failure misc hardware reason
    Load averages:                 1 minute   5 minute  15 minute
                                       0.00       0.00       0.00
Routing Engine status:
  Slot 1:
    Current state                  Master
    Election priority              Backup (default)
    Temperature                 44 degrees C / 111 degrees F
    CPU temperature             48 degrees C / 118 degrees F
    DRAM                      2048 MB (2048 MB installed)
    Memory utilization          29 percent
    CPU utilization:
      User                       0 percent
      Background                 0 percent
      Kernel                     7 percent
      Interrupt                  0 percent
      Idle                      93 percent
    Model                          RE-A-2000
    Serial ID                      9012002390
    Start time                     2018-10-15 10:37:36 IST
    Uptime                         4 days, 22 minutes, 20 seconds
    Last reboot reason             Router rebooted after a normal shutdown.
    Load averages:                 1 minute   5 minute  15 minute
                                       0.11       0.09       0.04
 
 
[MASTER]
lab@M120-R1> show chassis fpc
Oct 19 11:02:05
                     Temp  CPU Utilization (%)   Memory    Utilization (%)
Slot State            (C)  Total  Interrupt      DRAM (MB) Heap     Buffer
  0  Online            50      0          0       128         7         51
  1  Online            43      0          0       128         7         51
  2  Online            35      0          0       128         9         51
  3  Empty          
  4  Online            30      0          0       128        11         51
  5  Empty          
 

When RE switchover occurs, the following may be observed:

[MASTER]
lab@M120-R1> request chassis routing-engine master switch
Oct 19 11:03:20
Toggle mastership between routing engines ? [yes,no] (no) yes
Oct 19 11:03:26
 
Resolving mastership...
Complete. The other routing engine becomes the master.
 
[BACKUP]
lab@M120-R1>
 
Oct 19 11:03:48 CHASSISD_FRU_OFFLINE_NOTICE: Taking FPC 3 offline: FRU did not reconnect
Oct 19 11:03:48  fpc_down slot 3 reason Removal cargs 0x0
Oct 19 11:03:48  fpc_offline_now - slot 3, reason: FRU did not reconnect, error OK transition state 1
Oct 19 11:03:48  send: red alarm set, device FPC 4, reason FEB not online for FPC 4
Oct 19 11:03:48 CHASSISD_FRU_OFFLINE_NOTICE: Taking FPC 5 offline: FRU did not reconnect
Oct 19 11:03:48  fpc_down slot 5 reason Removal cargs 0x0
Oct 19 11:03:48  fpc_offline_now - slot 5, reason: FRU did not reconnect, error OK transition state 1

 

Solution:

When RE switchover occurs with GRES enabled, the chassisd attempts to do a soft reconnect on all the slots of the chassis regardless of whether or not an FPC is present. The above messages indicate that due to slot 3 and slot 5 being empty, there was no reconnect. Hence, the respective FPC slots were taken offline.

The slots that have FPCs will be able to successfully establish a soft reconnect and will operate normally without any impact as observed below:

Oct 19 11:03:26  FPC 0 added
Oct 19 11:03:26  reading FPC 0 initial state
Oct 19 11:03:26  check_and_carp_on_i2cs_version I2CS version=0xf
Oct 19 11:03:27  Done reading FPC 0 initial state
Oct 19 11:03:27  FPC 1 added
Oct 19 11:03:27  reading FPC 1 initial state
Oct 19 11:03:27  check_and_carp_on_i2cs_version I2CS version=0xf
Oct 19 11:03:28  Done reading FPC 1 initial state
Oct 19 11:03:28  FPC 2 added
Oct 19 11:03:28  reading FPC 2 initial state
Oct 19 11:03:28  check_and_carp_on_i2cs_version I2CS version=0xf
Oct 19 11:03:29  Done reading FPC 2 initial state
Oct 19 11:03:29  FPC 4 added
Oct 19 11:03:29  reading FPC 4 initial state
Oct 19 11:03:30  check_and_carp_on_i2cs_version I2CS version=0xf
Oct 19 11:03:30  Done reading FPC 4 initial state

It can also be noted from the uptime of the FPCs that the FPCs did not restart and only went through a soft restart with the chassisd process of the current master RE.

lab@M120-R1> show chassis fpc detail
Oct 19 11:38:07
Slot 0 information:
  State                               Online   
  Temperature                      50 degrees C / 122 degrees F
  Total CPU DRAM                  128 MB
  Start time                          2018-10-15 10:10:41 IST
  Uptime                              4 days, 1 hour, 27 minutes, 26 seconds
Slot 1 information:
  State                               Online   
  Temperature                      43 degrees C / 109 degrees F
  Total CPU DRAM                  128 MB
  Start time                          2018-10-15 10:10:43 IST
  Uptime                              4 days, 1 hour, 27 minutes, 24 seconds
Slot 2 information:
  State                               Online   
  Temperature                      35 degrees C / 95 degrees F
  Total CPU DRAM                  128 MB
  Start time                          2018-10-15 10:10:46 IST
  Uptime                              4 days, 1 hour, 27 minutes, 21 seconds
Slot 4 information:
  State                               Online   
  Temperature                      31 degrees C / 87 degrees F
  Total CPU DRAM                  128 MB
  Start time                          2018-10-15 10:10:54 IST
  Uptime                              4 days, 1 hour, 27 minutes, 13 seconds
Comment on this article > Affected Products Browse the Knowledge Base for more articles related to these product categories. Select a category to begin.

Getting Up and Running with Junos

Getting Up and Running with Junos Security Alerts and Vulnerabilities Product Alerts and Software Release Notices Problem Report (PR) Search Tool EOL Notices and Bulletins JTAC User Guide Customer Care User Guide Pathfinder SRX High Availability Configurator SRX VPN Configurator Training Courses and Videos End User Licence Agreement Global Search