[QFX] Performing checks on QFabric DG hard drives

  [KB33562] Show Article Properties


Summary:

This article provides the required steps to check the integration of HDD and SCSI controllers on QFabric, and also the steps to identify any problems on the hard drives in case of SCSI errors.

 

Symptoms:

The symptoms could be any unprecedented behavior on QFabric. A few observations include the following:

  • HDD read write failure

  • VM malfunctioning (for example, NNG VM ungraceful switchover causing external l3 protocol to flap)

  • Node disconnection (again can be due to FM VM malfunctioning)

  • DG mastership switchover in an unregulated condition

Due to SCSI errors and the above symptoms, the network being down is highly possible.

 

Solution:

Note: You need to log in to both DGs via the console or SSH. The checks on the DGs will not impact existing operations.

  1. Start with log collection.
[root@dg0 /]# cd vmm
[root@dg0 logs]# pwd
/vmm/logs
  1. Analyze the following logs:
    • [root@dg0 logs]# cat ccif_server.log | grep "Fri, May 11 2018" (Collect the complete log.)

    • [root@dg0 /]# cat /var/log/messages | grep scsi (Look for SCSI controller related errors.)

    • [root@dg0 /]# /pbdata/usr/mysql-5.5.28/data
      dg0.err
      dg1.err
      [labroot@dg0 ~]# cat /sys/block/sd*/device/timeout
      [labroot@dg0 ~]# cat /sys/block/sd*/device/timeout
 

SCSI Data Collection

Collect the SCSI commands data from the DG-0 and DG-1 shell level. The commands along with the expected outputs are as follows:

Note: In working condition, the volume must show as "OPTIMAL." It can show "DEGRADED" if one of the HDDs in either DG is not online.

[root@dg0 ~]# disk_status.sh -r
vol_id:0B37315D2C885E21 OPTIMAL
phys_id:0 ONLINE
phys_id:1 ONLINE
scsi_id:0 0%
scsi_id:1 0%

[root@dg0 ~]# /root/mpt-status -i 4 -s -n -p
Checking for SCSI ID:0
Checking for SCSI ID:1
Checking for SCSI ID:2
Checking for SCSI ID:3
Checking for SCSI ID:4
Checking for SCSI ID:5
Checking for SCSI ID:6
Checking for SCSI ID:7
Checking for SCSI ID:8
Checking for SCSI ID:9
Checking for SCSI ID:10
vol_id:10 OPTIMAL
phys_id:0 ONLINE
phys_id:1 ONLINE
scsi_id:0 100%
scsi_id:1 100%
 

A few important utility commands (working state output) are as follows. Make sure that you capture the output on both DGs.

[root@dg1 ~]# lsutil
-bash: lsutil: command not found
[root@dg1 ~]# /root/mpt-status -i 4 -s -n -p
Checking for SCSI ID:0
Checking for SCSI ID:1
Checking for SCSI ID:2
Checking for SCSI ID:3
Checking for SCSI ID:4
Checking for SCSI ID:5
Checking for SCSI ID:6
Checking for SCSI ID:7
Checking for SCSI ID:8
vol_id:8 OPTIMAL
phys_id:1 ONLINE
phys_id:0 ONLINE
scsi_id:1 100%
scsi_id:0 100%


[root@dg0 ~]# smartctl -a -T permissive /dev/sg0 <<< SG0 & SG1 define HDD0 & HDD1, respectively. Change attributes accordingly to check both HDDs.
smartctl version 5.38 [x86_64-redhat-linux-gnu] Copyright (C) 2002-8 Bruce Allen
Home page is http://smartmontools.sourceforge.net/
=== START OF INFORMATION SECTION ===
Device Model: WDC WD2000FYYZ-01UL1B2
Serial Number: WD-WMC1P0E37UTL
Firmware Version: 01.01K03
User Capacity: 2,000,398,934,016 bytes
Device is: Not in smartctl database [for details use: -P show all]
ATA Version is: 8
ATA Standard is: Exact ATA specification draft version not indicated
Local Time is: Fri May 11 11:31:51 2018 UTC
SMART support is: Available - device has SMART capability.
SMART support is: Enabled
Error SMART Status command failed
Please get assistance from http://smartmontools.sourceforge.net/
Values from ATA Return Descriptor are:
00 09 0c 00 00 00 00 00 00 00 00 00 00 00 00
=== START OF READ SMART DATA SECTION ===
SMART overall-health self-assessment test result: PASSED
General SMART Values:
Offline data collection status:     (0x84) Offline data collection activity
                                                was suspended by an interrupting command from
host.
                                                 Auto Offline Data Collection:Enabled.
Self-test execution status:          ( 0) The previous self-test routine completed
                                                without error or no self-test has ever
                                                 been run.
Total time to complete Offline
data collection:                            (24660) seconds.
Offline data collection
capabilities:                                      (0x7b) SMART execute Offline immediate.
                                                        Auto Offline data collection on/off support.
                                                        Suspend Offline collection upon new
                                                        command.
                                                        Offline surface scan supported.
                                                        Self-test supported.
                                                        Conveyance Self-test supported.
                                                        Selective Self-test supported.
SMART capabilities:                           (0x0003) Saves SMART data before entering
                                                        power-saving mode.
                                                        Supports SMART auto save timer.
Error logging capability:                      (0x01) Error logging supported.
                                                        General Purpose Logging supported.
Short self-test routine
recommended polling time:                   ( 2) minutes.
Extended self-test routine
recommended polling time:                   ( 255) minutes.
Conveyance self-test routine
recommended polling time:                    ( 5) minutes.
SCT capabilities:                                   (0x70bd) SCT Status supported.
                                                            SCT Feature Control supported.
                                                            SCT Data Table supported.

SMART Attributes Data Structure revision number: 16

Vendor Specific SMART Attributes with Thresholds:

ID#    ATTRIBUTE_NAME            FLAG     VALUE    WORST   THRESH    TYPE       UPDATED   WHEN_FAILED  RAW_VALUE
1      Raw_Read_Error_Rate       0x002f   200      200     051       Pre-fail   Always    -            0
3      Spin_Up_Time              0x0027   169      166     021       Pre-fail   Always    -            6525
4      Start_Stop_Count          0x0032   100      100     000       Old_age    Always    -            167
5      Reallocated_Sector_Ct     0x0033   200      200     140       Pre-fail   Always    -            0
7      Seek_Error_Rate           0x002e   200      200     000       Old_age    Always    -            0
9      Power_On_Hours            0x0032   076      076     000       Old_age    Always    -            17710
10     Spin_Retry_Count          0x0032   100      100     000       Old_age    Always    -            0
11     Calibration_Retry_Count   0x0032   100      100     000       Old_age    Always    -            0
12     Power_Cycle_Count         0x0032   100      100     000       Old_age    Always    -            167
183    Unknown_Attribute         0x0032   100      100     000       Old_age    Always    -            0
192    Power-Off_Retract_Count   0x0032   200      200     000       Old_age    Always    -            165
193    Load_Cycle_Count          0x0032   200      200     000       Old_age    Always    -            1
194    Temperature_Celsius       0x0022   120      110     000       Old_age    Always    -            30
196    Reallocated_Event_Count   0x0032   200      200     000       Old_age    Always    -            0
197    Current_Pending_Sector    0x0032   200      200     000       Old_age    Always    -            0
198    Offline_Uncorrectable     0x0030   200      200     000       Old_age    Offline   -            0
199    UDMA_CRC_Error_Count      0x0032   200      200     000       Old_age    Always    -            0
200    Multi_Zone_Error_Rate     0x0008   200      200     000       Old_age    Offline   -            0

SMART Error Log Version: 1
No Errors Logged
SMART Self-test log structure revision number 1
No self-tests have been logged. [To run self-tests, use: smartctl -t]
SMART Selective self-test log data structure revision number 1
SPAN          MIN_LBA     MAX_LBA   CURRENT_TEST_STATUS
1                         0                     0                    Not_testing
2                         0                     0                    Not_testing
3                         0                     0                    Not_testing
4                         0                     0                    Not_testing
5                         0                     0                    Not_testing
Selective self-test flags (0x0):
After scanning selected spans, do NOT read-scan remainder of disk.
If Selective self-test is pending on power-up, resume after 0 minute delay.


[root@dg0 ~]# lsiutil (Follow the bold options to run the utility.)

LSI Logic MPT Configuration Utility, Version 1.67, September 15, 2011
1 MPT Port found
Port Name Chip Vendor/Type/Rev MPT Rev Firmware Rev IOC
1. /proc/mpt/ioc0 LSI Logic SAS1068E B3 105 01210000 0
Select a device: [1-1 or 0 to quit] 1
1. Identify firmware, BIOS, and/or FCode
2. Download firmware (update the FLASH)
4. Download/erase BIOS and/or FCode (update the FLASH)
8. Scan for devices
10. Change IOC settings (interrupt coalescing)
13. Change SAS IO Unit settings
16. Display attached devices
20. Diagnostics
21. RAID actions
22. Reset bus

SAS1068E's     links are    3.0 G,     3.0 G,     down,     down,    down,    down,   down,    down
B___T___L       Type         Vendor     Product                 Rev                    SASAddress      PhyNum
0    10    0        Disk          LSILOGIC Logical Volume     3000
Hidden RAID Devices:
B___T        Device          Vendor     Product                       Rev        SASAddress           PhyNum
0      11      PhysDisk 0   ATA         WDC WD2000FYYZ-0  1K03      a2984920c1abc18c      1
0       12     PhysDisk 1   ATA        WDC WD2000FYYZ-0  1K03      a2984921a6cccd88       0

Main menu, select an option: [1-99 or e/p/w or 0 to quit] 1
Current active firmware version is 011e0000 (1.30.00)
Firmware image's version is MPTFW-01.30.00.00-IE
LSI Logic
x86 BIOS image's version is MPTBIOS-6.30.00.00 (2009.11.12)

Main menu, select an option: [1-99 or e/p/w or 0 to quit] 0

Main menu, select an option: [1-99 or e/p/w or 0 to quit] 0

    Port Name         Chip Vendor/Type/Rev       MPT Rev  Firmware Rev  IOC
1. /proc/mpt/ioc0    LSI Logic SAS1068E B3   105          011e0000        0

Select a device: [1-1 or 0 to quit] 1
Main menu, select an option: [1-99 or e/p/w or 0 to quit]
1. Identify firmware, BIOS, and/or FCode
2. Download firmware (update the FLASH)
4. Download/erase BIOS and/or FCode (update the FLASH)
8. Scan for devices
10. Change IOC settings (interrupt coalescing)
13. Change SAS IO Unit settings
16. Display attached devices
20. Diagnostics
21. RAID actions
22. Reset bus

    Port Name        Chip Vendor/Type/Rev         MPT Rev     Firmware Rev   IOC
1. /proc/mpt/ioc0   LSI Logic SAS1068E B3     105              011e0000         0


Main menu, select an option: [1-99 or e/p/w or 0 to quit]  16
SAS1068E's   links are   3.0 G,    3.0 G,     down,    down,    down,    down,    down,    down
 B___T           SASAddress    PhyNum        Handle          Parent               Type
                     500e08101037b7a0                0001                                      SAS Initiator
                     500e08101037b7a1                0002                                      SAS Initiator
                     500e08101037b7a2                0003                                      SAS Initiator
                     500e08101037b7a3                0004                                      SAS Initiator
                     500e08101037b7a4                0005                                      SAS Initiator
                     500e08101037b7a5                0006                                      SAS Initiator
                     500e08101037b7a6                0007                                      SAS Initiator
                     500e08101037b7a7                0008                                      SAS Initiator
0 12               a2984921a6cccd88    0          0009                0001               SATA Target
0 11                 a2984920c1abc18c 1           000a                0002                SATA Target
Type                 NumPhys                 PhyNum              Handle              PhyNum             Handle      Port    Speed [Disk speed must match for both HDDs.]
Adapter               8                      0                   0001 -->            0                  0009        0       3.0
                                                           1                       0002 -->            0                        000a             1          3.0        [If there is speed mismatch, use KB32952.]
Enclosure      Handle        Slots            SASAddress                                        B___T (SEP)
                      0001            8               500e08101037b7a0


Main menu, select an option: [1-99 or e/p/w or 0 to quit] 0

     Port Name        Chip Vendor/Type/Rev       MPT Rev      Firmware   Rev    IOC
1. / proc/mpt/ioc0   LSI Logic SAS1068E B3   105              01210000            0

Select a device: [1-1 or 0 to quit] 1
1. Identify firmware, BIOS, and/or FCode
2. Download firmware (update the FLASH)
4. Download/erase BIOS and/or FCode (update the FLASH)
8. Scan for devices
10. Change IOC settings (interrupt coalescing)
13. Change SAS IO Unit settings
16. Display attached devices
20. Diagnostics
21. RAID actions

Main menu, select an option: [1-99 or e/p/w or 0 to quit] 21
1. Show volumes
2. Show physical disks

1 volume is active, 2 physical disks are active
Volume 0 is Bus 0 Target 10, Type IM (Integrated Mirroring)
Volume Name:
Volume WWID: 0b37315d2c885e21
Volume State: optimal, enabled
Volume Settings: write caching disabled, auto configure
Volume draws from Hot Spare Pools: 0
Volume Size 1907348 MB, 2 Members
Primary is PhysDisk 0 (Bus 0 Target 11)
Secondary is PhysDisk 1 (Bus 0 Target 12)

RAID actions menu, select an option: [1-99 or e/p/w or 0 to quit] 2
1 volume is active, 2 physical disks are active
PhysDisk 0 is Bus 0 Target 11
PhysDisk State: online
PhysDisk Size 1907729 MB, Inquiry Data: ATA WDC WD2000FYYZ-0 1K03
Warning, page length in reply does not match page length in buffer
(9 vs. 15)
PhysDisk 1 is Bus 0 Target 12
PhysDisk State: online
PhysDisk Size 1907729 MB, Inquiry Data: ATA WDC WD2000FYYZ-0 1K03
Warning, page length in reply does not match page length in buffer
(9 vs. 15)

RAID actions menu, select an option: [1-99 or e/p/w or 0 to quit] 3
Volume 0 is Bus 0 Target 10, Type IM (Integrated Mirroring)
Volume 0 State: optimal, enabled

 