[SRX] Understanding how temperature sensors affect FAN speed and Alarm

0

0

Article ID: KB33967 KB Last Updated: 16 Mar 2019Version: 1.0
Summary:

This article explains which temperature sensors affect FAN speed and Alarm in SRX5K.

Symptoms:

Upon FAN Speed change and yellow/red alarm is generated, user cannot identify which particular temperature sensor triggered this. 

Example for yellow alarm:

labroot@jtac-srx5800-r2026> show chassis alarms 
2 alarms currently active
Alarm time               Class  Description
2019-02-27 03:39:50 UTC  Minor  Temperature Warm
2019-02-26 04:10:40 UTC  Minor  CB Fabric Throughput Decreased

Message log for FAN Speed change

Feb 27 03:20:44  jtac-srx5800-r2026 chassisd[1556]: CHASSISD_BLOWERS_SPEED_FULL: Fans and impellers being set to full speed [system warm]
Cause:

There are multiple sensors in SPCII and IOCII but it is NOT clear which sensor affects FAN speed and ALARM in SRX5K.

labroot@jtac-srx5800-r2026> show chassis hardware 
Hardware inventory:
Item             Version  Part number  Serial number     Description
Chassis                                XXXXXXXXXXXX      SRX5800
Routing Engine 0 REV 02   740-056658   XXXXXXXXXX        SRX5k RE-1800X4
FPC 0            REV 24   750-061489   XXXXXXXX          SRX5k SPC II
FPC 3            REV 08   750-061262   XXXXXXXX          SRX5k IOC II

labroot@jtac-srx5800-r2026> show chassis environment 
Class Item                           Status     Measurement
<SNIP>
      FPC 0 Intake                   OK         37 degrees C / 98 degrees F
      FPC 0 Exhaust A                OK         49 degrees C / 120 degrees F
      FPC 0 Exhaust B                OK         59 degrees C / 138 degrees F
      FPC 0 LU TSen                  OK         58 degrees C / 136 degrees F
      FPC 0 LU Chip                  OK         55 degrees C / 131 degrees F
      FPC 0 XM TSen                  OK         58 degrees C / 136 degrees F
      FPC 0 XM Chip                  OK         64 degrees C / 147 degrees F
      FPC 0 xlp0 TSen                OK         57 degrees C / 134 degrees F
      FPC 0 xlp0 Chip                OK         52 degrees C / 125 degrees F
      FPC 0 xlp1 TSen                OK         58 degrees C / 136 degrees F
      FPC 0 xlp1 Chip                OK         51 degrees C / 123 degrees F
      FPC 0 xlp2 TSen                OK         49 degrees C / 120 degrees F
      FPC 0 xlp2 Chip                OK         48 degrees C / 118 degrees F
      FPC 0 xlp3 TSen                OK         55 degrees C / 131 degrees F
      FPC 0 xlp3 Chip                OK         48 degrees C / 118 degrees F
      FPC 3 Intake                   OK         38 degrees C / 100 degrees F
      FPC 3 Exhaust A                OK         32 degrees C / 89 degrees F
      FPC 3 Exhaust B                OK         60 degrees C / 140 degrees F
      FPC 3 LU 0 TSen                OK         48 degrees C / 118 degrees F
      FPC 3 LU 0 Chip                OK         43 degrees C / 109 degrees F
      FPC 3 LU 1 TSen                OK         48 degrees C / 118 degrees F
      FPC 3 LU 1 Chip                OK         57 degrees C / 134 degrees F
      FPC 3 LU 2 TSen                OK         48 degrees C / 118 degrees F
      FPC 3 LU 2 Chip                OK         60 degrees C / 140 degrees F
      FPC 3 LU 3 TSen                OK         48 degrees C / 118 degrees F
      FPC 3 LU 3 Chip                OK         68 degrees C / 154 degrees F
      FPC 3 XM 0 TSen                OK         48 degrees C / 118 degrees F
      FPC 3 XM 0 Chip                OK         62 degrees C / 143 degrees F
      FPC 3 XF 0 TSen                OK         48 degrees C / 118 degrees F
      FPC 3 XF 0 Chip                OK         79 degrees C / 174 degrees F
      FPC 3 PLX Switch TSen          OK         48 degrees C / 118 degrees F
      FPC 3 PLX Switch Chip          OK         53 degrees C / 127 degrees F
Solution:

FAN Speed and yellow/red alarms are affected by Intake/Exhaust A/Exhaust B sensors in both SPCII and IOCII.  TSen/Chip sensors do not affect FAN Speed and yellow/red alarm.

The following test was done on SRX5800 running 15.1X49-D160.  Temperature threshold is adjusted by hidden command to demonstrate this behavior.

FAN Speeding testing in SPCII 

//High Fan threshold in FPC 0(SPCII) changes from 60 to 59 by hidden command

labroot@jtac-srx5800> show chassis temperature-thresholds 
                           Fan speed      Yellow alarm      Red alarm      Fire Shutdown
                          (degrees C)      (degrees C)     (degrees C)      (degrees C)
Item                     Normal  High   Normal  Bad fan   Normal  Bad fan     Normal
Chassis default              48    54       65       55       75       65      100
Routing Engine 0             70    80       95       95      110      110      112
FPC 0                        55    59       75       65       90       80       95
FPC 3                        55    60       75       65       90       80       95

//Exhaust B reaches 59c, FAN speed should not change to High Speed

labroot@jtac-srx5800> show chassis environment fpc 0 
FPC 0 status:
  State                      Online
  Temperature Intake         37 degrees C / 98 degrees F             
  Temperature Exhaust A      49 degrees C / 120 degrees F            
  Temperature Exhaust B      59 degrees C / 138 degrees F 
          
  Temperature LU TSen        58 degrees C / 136 degrees F            
  Temperature LU Chip        54 degrees C / 129 degrees F            
  Temperature XM TSen        58 degrees C / 136 degrees F            
  Temperature XM Chip        63 degrees C / 145 degrees F            
  Temperature xlp0 TSen      56 degrees C / 132 degrees F            
  Temperature xlp0 Chip      51 degrees C / 123 degrees F            
  Temperature xlp1 TSen      58 degrees C / 136 degrees F            
  Temperature xlp1 Chip      51 degrees C / 123 degrees F            
  Temperature xlp2 TSen      49 degrees C / 120 degrees F            
  Temperature xlp2 Chip      47 degrees C / 116 degrees F            
  Temperature xlp3 TSen      54 degrees C / 129 degrees F            
  Temperature xlp3 Chip      47 degrees C / 116 degrees F            
  Power                      
    1.0 V                       1002 mV
    1.05 V                      1056 mV 
    1.5 V                       1506 mV
    1.8 V                       1796 mV
    2.5 V                       2500 mV
    3.3 V                       3312 mV
  I2C Slave Revision         10
 

//Message log shown FAN speed change to High Speed 

Feb 27 03:20:44  jtac-srx5800 chassisd[1556]: CHASSISD_BLOWERS_SPEED_FULL: Fans and impellers being set to full speed [system warm]
 

Yellow Alarm testing in SPCII

//Yellow alarm threshold in FPC 0 (SPCII) changes from 75 to 30 by hidden command

labroot@jtac-srx5800# run show chassis temperature-thresholds 
                           Fan speed      Yellow alarm      Red alarm      Fire Shutdown
                          (degrees C)      (degrees C)     (degrees C)      (degrees C)
Item                     Normal  High   Normal  Bad fan   Normal  Bad fan     Normal
Chassis default              48    54       65       55       75       65      100
Routing Engine 0             70    80       95       95      110      110      112
FPC 0                        55    60       30       65       90       80       95
FPC 3                        55    60       75       65       90       80       95

//3 message log generated with each corresponded to Intake/Exhaust A/Exhaust B Sensors.
Feb 27 03:27:47  jtac-srx5800 chassisd[1556]: CHASSISD_SNMP_TRAP6: SNMP trap generated: Over Temperature! (jnxContentsContainerIndex 7, jnxContentsL1Index 1, jnxContentsL2Index 0, jnxContentsL3Index 0, jnxContentsDescr FPC: SRX5k SPC II @ 0/*/*, jnxOperatingState/Temp 49)  <-- Exhause A Sensor
Feb 27 03:27:47  jtac-srx5800 chassisd[1556]: CHASSISD_SNMP_TRAP6: SNMP trap generated: Over Temperature! (jnxContentsContainerIndex 7, jnxContentsL1Index 1, jnxContentsL2Index 0, jnxContentsL3Index 0, jnxContentsDescr FPC: SRX5k SPC II @ 0/*/*, jnxOperatingState/Temp 59)  <-- Exhaust B Sensor
Feb 27 03:27:47  jtac-srx5800 chassisd[1556]: CHASSISD_SNMP_TRAP6: SNMP trap generated: Over Temperature! (jnxContentsContainerIndex 7, jnxContentsL1Index 1, jnxContentsL2Index 0, jnxContentsL3Index 0, jnxContentsDescr FPC: SRX5k SPC II @ 0/*/*, jnxOperatingState/Temp 37)  <-- Intake Sensor 
 

FAN Speeding testing in IOCII

//Normal Fan threshold in FPC 3(IOCII) changes from 55 to 57 by hidden command

labroot@jtac-srx5800> show chassis temperature-thresholds 
                           Fan speed      Yellow alarm      Red alarm      Fire Shutdown
                          (degrees C)      (degrees C)     (degrees C)      (degrees C)
Item                     Normal  High   Normal  Bad fan   Normal  Bad fan     Normal
Chassis default              48    54       65       55       75       65      100
Routing Engine 0             70    80       95       95      110      110      112
FPC 0                        55    60       75       65       90       80       95
FPC 3                        57    60       75       65       90       80       95

//Exchaust B reaches 57, FAN speed should now change from High speed to Normal speed

labroot@jtac-srx5800> show chassis environment fpc 3 
FPC 3 status:
  State                      Online
  Temperature Intake         37 degrees C / 98 degrees F             
  Temperature Exhaust A      32 degrees C / 89 degrees F             
  Temperature Exhaust B      57 degrees C / 134 degrees F            
  Temperature LU 0 TSen      46 degrees C / 114 degrees F            
  Temperature LU 0 Chip      42 degrees C / 107 degrees F            
  Temperature LU 1 TSen      46 degrees C / 114 degrees F            
  Temperature LU 1 Chip      54 degrees C / 129 degrees F            
  Temperature LU 2 TSen      46 degrees C / 114 degrees F            
  Temperature LU 2 Chip      57 degrees C / 134 degrees F            
  Temperature LU 3 TSen      46 degrees C / 114 degrees F            
  Temperature LU 3 Chip      64 degrees C / 147 degrees F            
  Temperature XM 0 TSen      46 degrees C / 114 degrees F            
  Temperature XM 0 Chip      60 degrees C / 140 degrees F            
  Temperature XF 0 TSen      46 degrees C / 114 degrees F            
  Temperature XF 0 Chip      76 degrees C / 168 degrees F            
  Temperature PLX Switch TSen46 degrees C / 114 degrees F            
  Temperature PLX Switch Chip51 degrees C / 123 degrees F            
  Power                                 
    MPC-BIAS3V3-zl2105          3288 mV
    MPC-VDD3V3-zl6100           3283 mV
    MPC-VDD2V5-zl6100           2489 mV
    MPC-VDD1V8-zl2004           1797 mV
    MPC-AVDD1V0-zl2004           998 mV
    MPC-VDD1V2-zl6100           1197 mV
    MPC-VDD1V5A-zl2004          1496 mV
    MPC-VDD1V5B-zl2004          1499 mV
    MPC-XF_0V9-zl2004            997 mV
    MPC-PCIE_1V0-zl6100          997 mV
    MPC-LU0_1V0-zl2004           996 mV
    MPC-LU1_1V0-zl2004           996 mV
    MPC-LU2_1V0-zl2004           997 mV
    MPC-LU3_1V0-zl2004           993 mV
    MPC-12VA-BMR453            12014 mV
    MPC-12VB-BMR453            12000 mV
    MPC-PMB_1V1-zl2006          1104 mV
    MPC-XM_0V9-vt273m            912 mV
  I2C Slave Revision         111        

//Message log shown FAN speed change to Normal Speed 

Feb 27 07:34:22  jtac-srx5800 chassisd[1556]: CHASSISD_BLOWERS_SPEED: Fans and impellers are now running at normal speed

Yellow Alarm testing in IOCII

//Yellow alarm threshold in FPC 3(IOCII) changes from 75 to 30 by hidden command

labroot@jtac-srx5800> show chassis temperature-thresholds 
                           Fan speed      Yellow alarm      Red alarm      Fire Shutdown
                          (degrees C)      (degrees C)     (degrees C)      (degrees C)
Item                     Normal  High   Normal  Bad fan   Normal  Bad fan     Normal
Chassis default              48    54       65       55       75       65      100
Routing Engine 0             70    80       95       95      110      110      112
FPC 0                        59    60       75       65       90       80       95
FPC 3                        55    60       30       29       90       80       95

labroot@jtac-srx5800> show chassis environment fpc 3 
FPC 3 status:
  State                      Online
  Temperature Intake         38 degrees C / 100 degrees F            
  Temperature Exhaust A      33 degrees C / 91 degrees F             
  Temperature Exhaust B      58 degrees C / 136 degrees F 
          
  Temperature LU 0 TSen      48 degrees C / 118 degrees F            
  Temperature LU 0 Chip      43 degrees C / 109 degrees F            
  Temperature LU 1 TSen      48 degrees C / 118 degrees F            
  Temperature LU 1 Chip      55 degrees C / 131 degrees F            
  Temperature LU 2 TSen      48 degrees C / 118 degrees F            
  Temperature LU 2 Chip      58 degrees C / 136 degrees F            
  Temperature LU 3 TSen      48 degrees C / 118 degrees F            
  Temperature LU 3 Chip      65 degrees C / 149 degrees F            
  Temperature XM 0 TSen      48 degrees C / 118 degrees F            
  Temperature XM 0 Chip      60 degrees C / 140 degrees F            
  Temperature XF 0 TSen      48 degrees C / 118 degrees F            
  Temperature XF 0 Chip      76 degrees C / 168 degrees F            
  Temperature PLX Switch TSen48 degrees C / 118 degrees F            
  Temperature PLX Switch Chip52 degrees C / 125 degrees F            
  Power                                 
    MPC-BIAS3V3-zl2105          3287 mV
    MPC-VDD3V3-zl6100           3284 mV
    MPC-VDD2V5-zl6100           2488 mV
    MPC-VDD1V8-zl2004           1798 mV
    MPC-AVDD1V0-zl2004           998 mV
    MPC-VDD1V2-zl6100           1195 mV
    MPC-VDD1V5A-zl2004          1497 mV
    MPC-VDD1V5B-zl2004          1499 mV
    MPC-XF_0V9-zl2004            998 mV
    MPC-PCIE_1V0-zl6100          998 mV
    MPC-LU0_1V0-zl2004           996 mV
    MPC-LU1_1V0-zl2004           996 mV
    MPC-LU2_1V0-zl2004           997 mV
    MPC-LU3_1V0-zl2004           993 mV
    MPC-12VA-BMR453            12005 mV
    MPC-12VB-BMR453            12017 mV
    MPC-PMB_1V1-zl2006          1104 mV
    MPC-XM_0V9-vt273m            913 mV
  I2C Slave Revision         111        
 

//3 message log generated with each corresponded to Intake/Exhaust A/Exhaust B Sensors.

Feb 27 03:40:02  jtac-srx5800 chassisd[1556]: CHASSISD_SNMP_TRAP6: SNMP trap generated: Over Temperature! (jnxContentsContainerIndex 7, jnxContentsL1Index 4, jnxContentsL2Index 0, jnxContentsL3Index 0, jnxContentsDescr FPC: SRX5k IOC II @ 3/*/*, jnxOperatingState/Temp 33)   <==Exhaust A sensor
Feb 27 03:40:02  jtac-srx5800 chassisd[1556]: CHASSISD_SNMP_TRAP6: SNMP trap generated: Over Temperature! (jnxContentsContainerIndex 7, jnxContentsL1Index 4, jnxContentsL2Index 0, jnxContentsL3Index 0, jnxContentsDescr FPC: SRX5k IOC II @ 3/*/*, jnxOperatingState/Temp 58)   <==Exhaust B sensor
Feb 27 03:40:02  jtac-srx5800 chassisd[1556]: CHASSISD_SNMP_TRAP6: SNMP trap generated: Over Temperature! (jnxContentsContainerIndex 7, jnxContentsL1Index 4, jnxContentsL2Index 0, jnxContentsL3Index 0, jnxContentsDescr FPC: SRX5k IOC II @ 3/*/*, jnxOperatingState/Temp 38)   <==Intake Sensor
 

//Temperature Warm Alarm generated

labroot@jtac-srx5800> show chassis alarms 
2 alarms currently active
Alarm time               Class  Description
2019-02-27 03:39:50 UTC  Minor  Temperature Warm
2019-02-26 04:10:40 UTC  Minor  CB Fabric Throughput Decreased

Related Links

Comment on this article > Affected Products Browse the Knowledge Base for more articles related to these product categories. Select a category to begin.

Getting Up and Running with Junos

Getting Up and Running with Junos Security Alerts and Vulnerabilities Product Alerts and Software Release Notices Problem Report (PR) Search Tool EOL Notices and Bulletins JTAC User Guide Customer Care User Guide Pathfinder SRX High Availability Configurator SRX VPN Configurator Training Courses and Videos End User Licence Agreement Global Search