[EX] How to perform Routing Engine Junos update for EX8200

0

0

Article ID: KB34257 KB Last Updated: 02 Aug 2019Version: 1.0
Summary:
When replacing a RE on an EX8200, you may need to perform a Junos upgrade to match the Junos version of the active RE. There are two ways to perform the Junos upgrade: 
  1. Upgrade from the master RE after the swap is complete.
  2. Perform a USB if for some reason connectivity between master and backup RE is down.
Solution:

Upgrade from the master RE after the swap is complete

  1. After removing the routing engine and swapping it with the new one, make sure the new RE is powered on and it is detected by the chassis: 

    show chassis routing-engine (from the master RE)
  2. Check connectivity between master RE and backup:

    start shell
    ping -Ji re1

    Example output:

    root@jtac-EX8208-r001-re0> start shell user root
    root@jtac-EX8208-r001-re0:RE:0%
    root@jtac-EX8208-r001-re0:RE:0%
    root@jtac-EX8208-r001-re0:RE:0% ping -Ji re1
    PING re1 (128.0.0.5): 56 data bytes
    64 bytes from 128.0.0.5: icmp_seq=0 ttl=64 time=1.346 ms
    64 bytes from 128.0.0.5: icmp_seq=1 ttl=64 time=1.274 ms
    64 bytes from 128.0.0.5: icmp_seq=2 ttl=64 time=1.267 ms
    ^C
    --- re1 ping statistics ---
    3 packets transmitted, 3 packets received, 0% packet loss
    round-trip min/avg/max/stddev = 1.267/1.296/1.346/0.036 ms
  3. If there is connectivity, proceed with the upgrade via the Master RE. Make sure the Junos code is on the master RE in order to push it onto the new RE. Issue the following command from the master RE to push the image to the new RE:

    request system software add re1 /var/tmp/<image>  validate reboot

    Example output:

    root@jtac-EX8208-r001-re0> file list /var/tmp/
     /var/tmp/:
    .schema-cache/
    .snap/
    install/
    jinstall-ex-8200-15.1R6-S6.1-domestic-signed.tgz
    krt_rpf_filter.txt
    pfe_debug_commands
    pics/
    rtsdb/
    vi.recover/


    root@jtac-EX8208-r001-re0> request system software add re1 /var/tmp/jinstall-ex-8200-15.1R6-S6.1-domestic-signed.tgz validate reboot
    Verify the signature of the new package
    Verified jinstall-ex-8200-15.1R6-S6.1-domestic.tgz signed by PackageProductionRSA_2018 method RSA2048+SHA1
    WARNING: A reboot is required to install the software
    WARNING:     Use the 'request system reboot' command immediately
    Rebooting ...
    shutdown: [pid 1987]
    Shutdown NOW!
  4. After reboot, verify the new Junos is installed by issuing the following command:

    show version invoke-on all-routing-engines 

    root@jtac-EX8208-r001-re0> show version invoke-on all-routing-engines
    re0:
    --------------------------------------------------------------------------
    Hostname: jtac-EX8208-r001-re0
    Model: ex8208
    Junos: 14.1X53-D103
    JUNOS EX  Software Suite [14.1X53-D103]
    JUNOS FIPS mode utilities [14.1X53-D103]
    JUNOS Online Documentation [14.1X53-D103]
    JUNOS EX 8200 Software Suite [14.1X53-D103]
    JUNOS Web Management Platform Package [14.1X53-D103]
     
    re1:
    --------------------------------------------------------------------------
    Hostname: jtac-EX8208-r001-re1
    Model: ex8208
    Junos: 15.1R6-S6.2
    JUNOS EX  Software Suite [15.1R6-S6.2]
    JUNOS FIPS mode utilities [15.1R6-S6.2]
    JUNOS Online Documentation [15.1R6-S6.2]
    JUNOS EX 8200 Software Suite [15.1R6-S6.2]
    JUNOS Web Management Platform Package [15.1R6-S6.2]

Upgrade using USB if connectivity between master and backup RE is down

  1. Install the image on a formatted USB stick 

  2. Plug in the USB stick in the new routing Engine. Once you plug in a usb stick, you will get the following message

    umass1: Unigen Corporation PQS1000B1, rev 2.00/11.00, addr 3
    da1 at umass-sim1 bus 1 target 0 lun 0
    da1: <Unigen PQS1000 1100> Removable Direct Access SCSI-0 device
    da1: 40.000MB/s transfers
    da1: 980MB (2007040 512 byte sectors: 64H 32S/T 980C)

    Example output:

    root@jtac-EX8208-r001-re1> show log messages | match da1
    Apr 10 03:13:28  jtac-EX8208-r001-re1 /kernel: da1 at umass-sim1 bus 1 target 0 lun 0
    Apr 10 03:13:28  jtac-EX8208-r001-re1 /kernel: da1: <Unigen PQS1000 1100> Removable Direct Access SCSI-0 device
    Apr 10 03:13:28  jtac-EX8208-r001-re1 /kernel: da1: 40.000MB/s transfers
    Apr 10 03:13:28  jtac-EX8208-r001-re1 /kernel: da1: 980MB (2007040 512 byte sectors: 64H 32S/T 980C)
  3. Mount the usb to a directory so you can push the junos config from it by issuing the following command:

     mount_msdosfs /dev/da1s1 /mnt/

    Example output:

    root@jtac-EX8208-r001-re1> start shell user root
    root@jtac-EX8208-r001-re1:BK:1% mount_msdosfs /dev/da1s1 /mnt/
    root@jtac-EX8208-r001-re1:BK:1% cli
    root@jtac-EX8208-r001-re1> file list /mnt/ 
     
    /mnt/:
    System Volume Information/
    jinstall-ex-8200-15.1R6-S6.2-domestic-signed.tgz*
  4. Upgrade the backup RE from the /mnt directory by issuing the following command:

    request system software add /mnt/<package>

    Example output:

    root@jtac-EX8208-r001-re1> request system software add /mnt/jinstall-ex-8200-15.1R6-S6.2-domestic-signed.tgz
    NOTICE: Validating configuration against incoming-package.tgz.
    NOTICE: Use the 'no-validate' option to skip this if desired.
    Verify the signature of the new package
    Verified jinstall-ex-8200-15.1R6-S6.2-domestic.tgz signed by PackageProductionRSA_2018
    WARNING: A reboot is required to install the software
    WARNING:     Use the 'request system reboot' command immediately
  5. From the Master RE, reboot the backup RE using this command:

    request system reboot other-routing-engine    ​

    Example output:

    root@jtac-EX8208-r001-re0> request system reboot other-routing-engine   
     
    Rebooting re1
     
    root@jtac-EX8208-r001-re0> show chassis routing-engine 1 
    Routing Engine status:
      Slot 1:
        Current state                  Present
  6. After a few minutes, check the version on the backup RE by issuing the following command:

    show version invoke-on all-routing-engines

    Example output:

    root@jtac-EX8208-r001-re0> show version invoke-on all-routing-engines
    re0:
    --------------------------------------------------------------------------
    Hostname: jtac-EX8208-r001-re0
    Model: ex8208
    Junos: 14.1X53-D103
    JUNOS EX  Software Suite [14.1X53-D103]
    JUNOS FIPS mode utilities [14.1X53-D103]
    JUNOS Online Documentation [14.1X53-D103]
    JUNOS EX 8200 Software Suite [14.1X53-D103]
    JUNOS Web Management Platform Package [14.1X53-D103]
     
    re1:
    --------------------------------------------------------------------------
    Hostname: jtac-EX8208-r001-re1
    Model: ex8208
    Junos: 15.1R6-S6.2
    JUNOS EX  Software Suite [15.1R6-S6.2]
    JUNOS FIPS mode utilities [15.1R6-S6.2]
    JUNOS Online Documentation [15.1R6-S6.2]
    JUNOS EX 8200 Software Suite [15.1R6-S6.2]
    JUNOS Web Management Platform Package [15.1R6-S6.2]

     
Comment on this article > Affected Products Browse the Knowledge Base for more articles related to these product categories. Select a category to begin.

Getting Up and Running with Junos

Getting Up and Running with Junos Security Alerts and Vulnerabilities Product Alerts and Software Release Notices Problem Report (PR) Search Tool EOL Notices and Bulletins JTAC User Guide Customer Care User Guide Pathfinder SRX High Availability Configurator SRX VPN Configurator Training Courses and Videos End User Licence Agreement Global Search