[EX] LED Indicators do not light up on EX2300-48MP, EX3400-24T and EX2300-24MP platforms

0

0

Article ID: KB34772 KB Last Updated: 25 Jul 2019Version: 1.0
Summary:

LED indicators cannot be lit up even if there are cables connecting to the related ports on EX2300-48MP, EX3400-24T and EX2300-24MP platforms. This issue can be found on several JUNOS versions. It cannot be detected with the command, 'show chassis led' on EX2300-48MP or EX2300-24MP because the command is not supported on these switches.

Symptoms:

First, the following log messages are continuously recorded in the "messages" file whether the ports in the log are up or down.

Jul  4 01:01:45  Switch-EX2300-48MP dc-pfe: optic_set_activity_led:[FPC:0 PIC:0 Port:12 Chan:0 - Ifd Speed:0] Failed setting activity led to ON
Jul  4 01:01:45  Switch-EX2300-48MP fpc0 optic_set_activity_led:[FPC:0 PIC:0 Port:12 Chan:0 - Ifd Speed:0] Failed setting activity led to ON
Jul  4 01:01:45  Switch-EX2300-48MP mib2d[3921]: SNMP_TRAP_LINK_UP: ifIndex 550, ifAdminStatus up(1), ifOperStatus up(1), ifName ge-0/0/12
Jul  4 01:05:08  Switch-EX2300-48MP mib2d[3921]: SNMP_TRAP_LINK_DOWN: ifIndex 550, ifAdminStatus up(1), ifOperStatus down(2), ifName ge-0/0/12
Jul  4 01:05:08  Switch-EX2300-48MP mib2d[3921]: SNMP_TRAP_LINK_DOWN: ifIndex 513, ifAdminStatus up(1), ifOperStatus down(2), ifName irb.0
Jul  4 01:05:16  Switch-EX2300-48MP dc-pfe: optic_set_activity_led:[FPC:0 PIC:0 Port:7 Chan:0 - Ifd Speed:0] Failed setting activity led to ON
Jul  4 01:05:16  Switch-EX2300-48MP fpc0 optic_set_activity_led:[FPC:0 PIC:0 Port:7 Chan:0 - Ifd Speed:0] Failed setting activity led to ON
Jul  4 01:05:16  Switch-EX2300-48MP mib2d[3921]: SNMP_TRAP_LINK_UP: ifIndex 543, ifAdminStatus up(1), ifOperStatus up(1), ifName ge-0/0/7

Second, the physical LED indicators are out even when there are cables plugged into the ports. The picture below is an example:

Solution:

There is no functional impact per PR1361739. The switch works as expected even with no LED indicators lighting up. However, this is fixed-in JUNOS versions 19.2R2 and
19.1R2 per PR1428703.

NOTE: PR1428703 is still open, so the fixed versions may be different when investigation is completed.

Related Links

Comment on this article > Affected Products Browse the Knowledge Base for more articles related to these product categories. Select a category to begin.

Getting Up and Running with Junos

Getting Up and Running with Junos Security Alerts and Vulnerabilities Product Alerts and Software Release Notices Problem Report (PR) Search Tool EOL Notices and Bulletins JTAC User Guide Customer Care User Guide Pathfinder SRX High Availability Configurator SRX VPN Configurator Training Courses and Videos End User Licence Agreement Global Search