Knowledge Search


×
 

Syslog message: dc-pfe: BRCM_NH-,brcm_nh_target_bcast_create(),2377:Unable to get classid for nh 1718

  [KB34775] Show Article Properties


Summary:

This article explains the cause for the reported syslog message.

Symptoms:

When executing change/delete/remove configurations, and the syslog level is set to error, the following syslog message is reported:

Jul  4 09:26:07  ex3400 dc-pfe: BRCM_NH-,brcm_nh_target_bcast_create(),2377:Unable to get classid for nh 1718
Jul  4 09:26:07  ex3400 fpc0 BRCM_NH-,brcm_nh_target_bcast_create(),2377:Unable to get classid for nh 1718​​

Example:

root@ex3400# show system syslog 
Jul 04 09:24:21
file messages {
    any critical; 
}

root@ex3400# set system syslog file messages any error  <-- No log output.

root@ex3400# show system syslog 
file messages {
    any error;  <-- changed from 
}

root@ex3400# ... match brcm_nh_target_bcast_create
Jul  4 09:26:07  ex3400 dc-pfe: BRCM_NH-,brcm_nh_target_bcast_create(),2377:Unable to get classid for nh 1718
Jul  4 09:26:07  ex3400 fpc0 BRCM_NH-,brcm_nh_target_bcast_create(),2377:Unable to get classid for nh 1718
Solution:

This log message does not impact service and can be safely ignored.  It is expected if target broadcast is not configured.

To suppress repeating non-impacting messages, refer to KB9382 - How to prevent certain syslog messages from being written to the log file

Related Links: