[EX] CoS/QoS shaping rate with absolute value stopped working for EX4600 after rebooting

0

0

Article ID: KB35578 KB Last Updated: 24 Mar 2020Version: 1.0
Summary:

CoS shaping rate configured with absolute value may stop working on EX4600 platforms if the switch is rebooted. In this article, the Junos OS releases in which the issue is resolved and a workaround are given, along with the reason for such behavior.

 

Symptoms:

The CoS/QoS shaping rate is seen to stop working after rebooting the switch if shaping rate is defined with an absolute value.

Example Configuration

set class-of-service traffic-control-profiles QOS-TCP shaping-rate 50m

PFE Output Before Rebooting

{master:0}
root@jtac-ex4600-40f-r2002> start shell
root@jtac-ex4600-40f-r2002:RE:0% vty fpc0
 
TOR platform (1500 Mhz Pentium processor, 511MB memory, 0KB flash)
 
TFXPC0(jtac-ex4600-40f-r2002 vty)# show cos hw ifd_index 656
Unit : 0
 
populate temp_cos_halp_ifd (0x22faf620),0x22faf620
 
IFD: ge-0/0/22 (656), unit: 0 bcm_port 23 mmu_port 25 num_uc_qs 12 mc_qs 10 ext_qs 0 port_grp 3
===========================================================================================
 
EGRESS CONFIG:
Port 23 Gport 0x8000017
  AdmCtl: uc_lmt_en 0 mc_lmt_en 0
                 CtlParm    SP0    SP1    SP2    SP3
             MC Shrd Lmt      0   8172      0      0
            MC Sh ResVal      0      0      0      0
             UC Shrd Lmt  13332      0  21504      0
            UC Sh ResVal      0      0      0      0
            MC Color Lmt      0      0      0      0
          UC Col Yel Lmt      0      0      0      0
          UC Col Red Lmt      0      0      0      0
  S1: Gport 0x34009717
    S2: max_s2_nodes 5 used_s2_nodes: 0
     S2 Node: idx 0 Gport 0x34009817 MC Available 1
     S2 Node: idx 1 Gport 0x34009917 UC Available 0
             fc_set_id: 64953 queues active:
             Sched Params: Weight 1 mode 5 bw_flags 0x0
                Tx rate: 0 kbps Shape rate: 50000 kbps
      UCQ0  (HWQ 0) Gport 0x2405c128 s2_offset: 0
           Sched: Weight   1 mode 5 bw_flags 0x0
              Tx rate:        0 kbps Shape rate:     50000  kbps
           AdmCtrl: q_spid 0 q_min 48 shared_lmt    7 qlmt_en 0
                    qlmt_dyn 1 alpha 7 col_en 0 col_lmt_dyn 1
                    lmt_yel    0 off   12 red    0 off   12 sh_off   12

 
PFE Output After Rebooting

{master:0}
root@jtac-ex4600-40f-r2002> start shell
root@jtac-ex4600-40f-r2002:RE:0% vty fpc0
 
TOR platform (1500 Mhz Pentium processor, 511MB memory, 0KB flash)
 
TFXPC0(jtac-ex4600-40f-r2002 vty)# show cos hw ifd_index 656
Unit : 0
 
populate temp_cos_halp_ifd (0x22faf620),0x22faf620
 
IFD: ge-0/0/22 (656), unit: 0 bcm_port 23 mmu_port 25 num_uc_qs 12 mc_qs 10 ext_qs 0 port_grp 3
===========================================================================================
 
EGRESS CONFIG:
Port 23 Gport 0x8000017
  AdmCtl: uc_lmt_en 0 mc_lmt_en 0
                 CtlParm    SP0    SP1    SP2    SP3
             MC Shrd Lmt      0   8172      0      0
            MC Sh ResVal      0      0      0      0
             UC Shrd Lmt  13332      0  21504      0
            UC Sh ResVal      0      0      0      0
            MC Color Lmt      0      0      0      0
          UC Col Yel Lmt      0      0      0      0
          UC Col Red Lmt      0      0      0      0
  S1: Gport 0x34009717
    S2: max_s2_nodes 5 used_s2_nodes: 0
     S2 Node: idx 0 Gport 0x34009817 MC Available 1
     S2 Node: idx 1 Gport 0x34009917 UC Available 0
             fc_set_id: 64953 queues active:
             Sched Params: Weight 1 mode 5 bw_flags 0x0
                Tx rate: 0 kbps Shape rate: 0 kbps    <<<<<<<<<<<<<
      UCQ0  (HWQ 0) Gport 0x2405c128 s2_offset: 0
           Sched: Weight   1 mode 5 bw_flags 0x0
              Tx rate:        0 kbps Shape rate:        0 kbps  <<<<<<<<<<<
           AdmCtrl: q_spid 0 q_min 48 shared_lmt    7 qlmt_en 0
                    qlmt_dyn 1 alpha 7 col_en 0 col_lmt_dyn 1
                    lmt_yel    0 off   12 red    0 off   12 sh_off   12 

After rebooting, CoS fails to shape traffic as per configured rate as seen in the above output.

 

Cause:

As per PR1472223, when shaping is applied with an absolute value, bandwidth programming is not done correctly after reboot of the switch.

 

Solution:

This issue has been resolved in Junos OS releases 18.1R3-S9, 18.4R3, 19.1R3, 19.2R2, 19.3R2-S1, 19.3R3, 19.4R2, and 20.1R1 as per PR1472223.

Meanwhile, to work around the problem, remove the shaping-rate configuration, commit, re-apply it, and commit again.

 

Comment on this article > Affected Products Browse the Knowledge Base for more articles related to these product categories. Select a category to begin.

Getting Up and Running with Junos

Getting Up and Running with Junos Security Alerts and Vulnerabilities Product Alerts and Software Release Notices Problem Report (PR) Search Tool EOL Notices and Bulletins JTAC User Guide Customer Care User Guide Pathfinder SRX High Availability Configurator SRX VPN Configurator Training Courses and Videos End User Licence Agreement Global Search