Summary:

On a wide range of Junos devices, the alarm is triggered when there is a port speed change made on one of the ports residing on FPC/PIC. This behavior can be seen on both FPC and PIC since it depends on the hierarchy on which the port lies. 

Symptoms:

Active alarms start appearing on the device when new port speed changes are made and a reboot/restart has not been initiated.

root@jtac> show chassis alarms no-forwarding

1 alarms currently active
Alarm time               Class  Description
2020-04-07 16:15:43 PDT  Minor FPC 2 PIC 0 Need bounce

OR

root@jtac> show chassis alarms no-forwarding

1 alarms currently active
Alarm time               Class  Description
2020-04-07 16:15:43 PDT  Minor  FPC 2 Need bounce
Cause:

When the following configuration change is made and ASIC is not re-initiated with this new configuration, the minor alarm could be triggered.

#set chassis fpc 2 pic 0 port 20 speed 10g
#commit
Solution:

Soft Restart:

In case of Minor alarm for PIC,

>request chassis pic fpc-slot fpc-slot-number pic-slot pic-slot-number offline
<wait for 2 minutes>
>request chassis pic fpc-slot fpc-slot-number pic-slot pic-slot-number online

In case of Minor alarm for FPC,

>request chassis fpc offline slot fpc-slot-number
<wait for 2 minutes>
>request chassis fpc online slot fpc-
slot-number

OR

>request chassis fpc restart slot fpc-slot-number

Hard Restart/ Re-seat:

Re-seat the FPC/PIC from the device manually to initiate a hard restart of the component.

Related Links

Comment on this article > Affected Products Browse the Knowledge Base for more articles related to these product categories. Select a category to begin.

Getting Up and Running with Junos

Getting Up and Running with Junos Security Alerts and Vulnerabilities Product Alerts and Software Release Notices Problem Report (PR) Search Tool EOL Notices and Bulletins JTAC User Guide Customer Care User Guide Pathfinder SRX High Availability Configurator SRX VPN Configurator Training Courses and Videos End User Licence Agreement Global Search