[QFX] Buffer allocation for VCP ports are not released in PFE after physically moving the port location

0

0

Article ID: KB36622 KB Last Updated: 24 Mar 2021Version: 1.0
Summary:

The QFX5200-32c 2 member virtual chassis with multiple VCP ports has a dedicated buffer allocation for each VC ports. When removing one of the VCP ports and relocating it to a different slot, the switch does not release the buffer allocation for the old port after its removed. 

Symptoms:

Current VC port location: 

{master:0}
root@qfx5200-32> show virtual-chassis 

Virtual Chassis ID: 3872.c0be.becd
Virtual Chassis Mode: Enabled
                                                Mstr           Mixed Route Neighbor List
Member ID  Status   Serial No    Model          prio  Role      Mode  Mode ID  Interface
0 (FPC 0)  Prsnt    WH0218160077 qfx5200-32c-32q 128  Master*      N  VC   1  vcp-255/0/0
                                                                           1  vcp-255/0/1
                                                                           1  vcp-255/0/2
                                                                           1  vcp-255/0/3
1 (FPC 1)  Prsnt    WH0218350005 qfx5200-32c-32q 128  Backup       N  VC   0  vcp-255/0/0
                                                                           0  vcp-255/0/1
                                                                           0  vcp-255/0/2
                                                                           0  vcp-255/0/3

New port location:

{master:0}
root@qfx5200-32> show virtual-chassis 

Virtual Chassis ID: 3872.c0be.becd
Virtual Chassis Mode: Enabled
                                                Mstr           Mixed Route Neighbor List
Member ID  Status   Serial No    Model          prio  Role      Mode  Mode ID  Interface
0 (FPC 0)  Prsnt    WH0218160077 qfx5200-32c-32q 128  Master*      N  VC   1  vcp-255/0/0
                                                                           1  vcp-255/0/22
                                                                           1  vcp-255/0/29
                                                                           1  vcp-255/0/4
1 (FPC 1)  Prsnt    WH0218350005 qfx5200-32c-32q 128  Backup       N  VC   0  vcp-255/0/0
                                                                           0  vcp-255/0/22
                                                                           0  vcp-255/0/29
                                                                           0  vcp-255/0/4
After moving the VC ports, the PFE will not release the allocated buffer for vcp-255/0/1 or vcp-255/0/2 and it will assign a new buffer for replacement ports vcp-255/0/22 and vcp-255/0/29
Solution:

To avoid this issue, make sure you delete the VCP ports from CLI first using "request virtual-chassis vc-port delete pic-slot <> port <>"  before moving the VCP ports physically. 

If the ports were moved before deleting them from CLI, then a complete system reboot will fix this issue. 

Comment on this article > Affected Products Browse the Knowledge Base for more articles related to these product categories. Select a category to begin.

Getting Up and Running with Junos

Getting Up and Running with Junos Security Alerts and Vulnerabilities Product Alerts and Software Release Notices Problem Report (PR) Search Tool EOL Notices and Bulletins JTAC User Guide Customer Care User Guide Pathfinder SRX High Availability Configurator SRX VPN Configurator Training Courses and Videos End User Licence Agreement Global Search