[MX] Points to note when working with MIC-MRATE (port profile) in a multi-speed environment

0

0

Article ID: KB37339 KB Last Updated: 06 Oct 2021Version: 1.0
Summary:

The MIC-MRATE and its derivatives (for example MPC7-MRATE) provide a mechanism called "port profile," which allows operators to select and use different port speeds.

This article details the points that need to be taken into account while using a port profile in your device.

Solution:

There are three possible modes of operation:

  1. The default mode

This mode is active when there is no explicit configuration under the chassis/FPC/PIC stanza. All inserted QSFP+ modules operate in the "channelized" (4 x 10G) mode. The system creates interface devices (IFD) for all ports on the MIC, irrespective of the physical presence of QSFP+.

  1. PIC-level port profile

In this mode, all the ports are configured uniformly:

chassis {
    fpc 0 {
        pic 0 {
            pic-mode 10G;
        }
    }
}

When the above configuration is committed, the MIC is power-cycled (bounced) automatically. Similar to the previous mode, the system creates interface devices (IFD) for all ports on the MIC.

  1. Port-level profile

This is the only mode that allows configuration of ports to operate at different speeds:

chassis {
    fpc 0 {
        pic 0 {
            port 0 {
                speed 40g;
            }
            port 1 {
                speed 40g;
            }
        }
    }
}

The granularity comes with a price, however. The following points need to be kept in mind while operating the MIC in this mode.

  1. A configuration change has to be activated manually.

Every time the speed-related configuration is altered and committed, the changes are not programmed immediately. Instead, the previous port profile is still in use until the MIC is power-cycled (bounced). In other words, an additional action has to be taken to make the changes effective. The system raises a minor alarm as a reminder of the pending action.

user@device> show chassis alarms
1 alarm currently active
Alarm time               Class  Description
2021-07-01 07:20:21 PDT  Minor  FPC 0 PIC 0 Need bounce

Note: This alarm might hinder other operational activities, for example a primary role switchover.

user@device> request chassis routing-engine master switch
warning: Traffic will be interrupted while the PFE is re-initialized
Toggle mastership between routing engines ? [yes,no] (no) yes

error: FPC0 PIC0 Need bounce

The power cycle can be conducted as follows:

user@device> request chassis mic fpc-slot 0 mic-slot 0 offline
fpc 0 mic 0 offline initiated, use "show chassis fpc pic-status 0" to verify

user@device> request chassis mic fpc-slot 0 mic-slot 0 online
fpc 0 mic 0 online initiated, use "show chassis fpc pic-status 0" to verify

Note: If an erroneous configuration is being committed (for example a port is incapable of operating at the configured speed), the system raises an alarm and continues using the port profile that was active prior to the change.

user@device> show chassis alarms
1 alarm currently active
Alarm time               Class  Description
2021-07-01 07:46:48 PDT  Minor  FPC 0 PIC 0 Invalid port profile configuration
  1. Only the explicitly configured ports are active.

Only the ports that are specified in the configuration are considered "active". The system creates the corresponding interface devices only for the active ports. Another important aspect is that "inactive" means that detection of a transceiver via I2C is also disabled. A short example follows.

Four QSFP+ are installed in MIC0/0:

user@device> show chassis pic fpc-slot 0 pic-slot 0
FPC slot 0, PIC slot 0 information:
  Type                             MRATE-12xQSFPP-XGE-XLGE-CGE
  State                            Online
  PIC version                 1.12
  Uptime                         15 seconds

PIC port information:
                         Fiber                    Xcvr vendor       Wave-    Xcvr         JNPR
  Port Cable type        type  Xcvr vendor        part number       length   Firmware     Rev
  0    40GBASE SR4       MM    AVAGO              AFBR-79EQPZ-JU1   850 nm   0.0          REV 01
  1    40GBASE SR4       MM    FINISAR CORP       FTL410QE3C-J1     850 nm   0.0          REV 01
  10   40GBASE SR4       MM    FINISAR CORP       FTL410QE4C-J1     850 nm   0.0          REV 01
  11   40GBASE SR4       MM    AVAGO              AFBR-79EQPZ-JU1   850 nm   0.0          REV 01

[snip]

By default, all ports operate at 10G and there are 12x4 = 48 IFDs.

user@device> show interfaces terse | match "^xe-0/0/[0-9]+:[0-3]\ +" | count
Count: 48 lines

Now let's convert the first port to 40G.

[edit]
+  chassis {
+      fpc 0 {
+          pic 0 {
+              port 0 {
+                  speed 40g;
+              }
+          }
+      }
+  }

When the configuration is committed and the MIC power-cycled, only one IFD is created.

user@device> show interfaces et-0/* terse
Interface               Admin Link Proto    Local                 Remote
et-0/0/0                up    down
et-0/0/0.16386          up    down

user@device> show interfaces xe-0/* terse

user@device>
  1. The QSFPs located in the inactive ports are not visible anymore.

After the previous configuration change, the QSFPs installed in ports 1, 10 and 11 became "invisible" in the CLI:

user@device> show chassis pic fpc-slot 0 pic-slot 0
FPC slot 0, PIC slot 0 information:
  Type                             MRATE-12xQSFPP-XGE-XLGE-CGE
  State                            Online
  PIC version                 1.12
  Uptime                         2 minutes, 45 seconds

PIC port information:
                         Fiber                    Xcvr vendor       Wave-    Xcvr         JNPR
  Port Cable type        type  Xcvr vendor        part number       length   Firmware     Rev
  0    40GBASE SR4       MM    AVAGO              AFBR-79EQPZ-JU1   850 nm   0.0          REV 01

[snip]

user@device> request pfe execute target fpc0 command "show qsfp list"
SENT: Ukern command: show qsfp list

QSFP Toolkit summary:
  wakeup count: 273262, debug: 0
  thread: 0xdeb47aa0, itable: 0xdeb17740

Index  Name       State
-----  ----       -----
    1  qsfp-0/0/0 Present
    2  qsfp-0/0/1 Absent
    3  qsfp-0/0/2 Absent
    4  qsfp-0/0/3 Absent
    5  qsfp-0/0/4 Absent
    6  qsfp-0/0/5 Absent
    7  qsfp-0/0/6 Absent
    8  qsfp-0/0/7 Absent
    9  qsfp-0/0/8 Absent
   10  qsfp-0/0/9 Absent
   11  qsfp-0/0/10 Absent
   12  qsfp-0/0/11 Absent

Takeaways and Recommended Best Current Practices

  • Avoiding the use of a default port profile aids in configuration readability.

  • Explicit port speed configuration eliminates the possibility of unexpected deactivation of ports when a non-default port speed is configured (due to [2]).

  • Postponing a PIC power cycle after a configuration change (for example, until the next Maintenance Window) might not be a good idea. Any unplanned events such as a PIC restart, a crash of the hosting FPC, or an ungraceful primary role switchover might activate the pending changes unexpectedly.

  • Since I2C polling is disabled on inactive ports, the installed QSFPs are not displayed in the CLI. Remember this fact always to avoid unnecessary hardware replacements.

Comment on this article > Affected Products Browse the Knowledge Base for more articles related to these product categories. Select a category to begin.

Getting Up and Running with Junos

Getting Up and Running with Junos Security Alerts and Vulnerabilities Product Alerts and Software Release Notices Problem Report (PR) Search Tool EOL Notices and Bulletins JTAC User Guide Customer Care User Guide Pathfinder SRX High Availability Configurator SRX VPN Configurator Training Courses and Videos End User Licence Agreement Global Search