Support Support Downloads Knowledge Base Case Manager My Juniper Community

Knowledge Base

Search our Knowledge Base sites to find answers to your questions.

Ask All Knowledge Base Sites All Knowledge Base Sites JunosE Defect (KA)Knowledge BaseSecurity AdvisoriesTechnical BulletinsTechnotes Sign in to display secure content and recently viewed articles

"show interfaces diagnostics optics" command issued on 100-Gigabit Ethernet OTN PIC with CFP2 (P2-100GE-OTN) with Coherent CFP2 module (CFP2-DCO-T-WDM-1) may report a false voltage warning/alarm

0

0

Article ID: TSB17517 TECHNICAL_BULLETINS Last Updated: 15 Feb 2019Version: 2.0
Alert Type:
PSN - Product Support Notification
Product Affected:
CFP2-DCO-T-WDM-1 (740-072229) under P2-100GE-OTN (750-069301)
Alert Description:
CFP has a feature to monitor its input voltage and validate with the preset threshold to provide warning or alarm through a certain Junos command. Because the voltage sensing circuitry on P2-100GE-OTN is confirmed to be not optimized for CFP2-DCO-T-WDM-1, Junos may falsely report a warning message as below, at "Module voltage" and "Module voltage low warning" row:
labroot@jtac-ptx3000-r2002> show interfaces diagnostics optics et-0/0/0 | no-more                
Physical interface: et-0/0/0
    Module temperature                        :  62 degrees C / 144 degrees F
    Module voltage                            :  3.2200 V
    Module temperature high alarm             :  Off
    Module temperature low alarm              :  Off
    Module temperature high warning           :  Off
    Module temperature low warning            :  Off
    Module voltage high alarm                 :  Off
    Module voltage low alarm                  :  Off
    Module voltage high warning               :  Off
    Module voltage low warning                :  On 
    Module not ready alarm                    :  Off
    Module low power alarm                    :  Off
    Module initialization incomplete alarm    :  Off
    Module fault alarm                        :  Off
    PLD Flash initialization fault alarm      :  Off
    Power supply fault alarm                  :  Off
    Checksum fault alarm                      :  Off
    Tx laser disabled alarm                   :  Off
    Rx loss of signal alarm                   :  Off
    Module temperature high alarm threshold   :  75 degrees C / 167 degrees F
    Module temperature low alarm threshold    :  -5 degrees C / 23 degrees F
    Module temperature high warning threshold :  70 degrees C / 158 degrees F
    Module temperature low warning threshold  :  0 degrees C / 32 degrees F
    Module voltage high alarm threshold       :  3.3990 V
    Module voltage low alarm threshold        :  3.1990 V
    Module voltage high warning threshold     :  3.3690 V
    Module voltage low warning threshold      :  3.2300 V 
<...>

This issue is tracked under PR1394266.

Solution:
The "Module voltage low warning" and "Module voltage low alarm" in "show interfaces diagnostics optics" output can be safely ignored.
Implementation:
The warning and/or alarm condition can be safely ignored, and no RMA is needed. Should there be any other problematic condition along with the voltage low warning/alarm as above, please consult with JTAC for further investigation.
Comment on this article > Affected Products Browse the Knowledge Base for more articles related to these product categories. Select a category to begin.

Getting Up and Running with Junos

Getting Up and Running with Junos Security Alerts and Vulnerabilities Product Alerts and Software Release Notices Problem Report (PR) Search Tool EOL Notices and Bulletins JTAC User Guide Customer Care User Guide Pathfinder SRX High Availability Configurator SRX VPN Configurator Training Courses and Videos End User Licence Agreement Global Search