PR Number | Synopsis | Category: MPC11 ULC interface software related issues. |
---|---|---|
1470796 | MPC11: After performing the offline_online event on pic snmp trap is not generated |
On MPC11, PIC Online event does not generate SNMP trap when PIC goes through Offline to Online transition. |
PR Number | Synopsis | Category: Marvell based EX PFE L2 |
---|---|---|
1474808 | Continuous dcpfe error messages and eventd process hogged might be seen on EX2300 VC scenario |
On EX2300 VC scenario, when host path packets are flooding through internal HG (higig) port, it might generate some dcpfe error messages which are harmless and eventd process hogged might also be seen. And it also might cause high CPU utilization which might affect protocol traffic. |
PR Number | Synopsis | Category: EX2300/3400 platform |
1477165 | EX3400 me0 interface might remain down |
The me0 interface of EX3400 does not come up when connected to 100m speed interface. |
PR Number | Synopsis | Category: NFX Layer 3 Features Software |
1449278 | NFX-150's heth-4/5 ports don't see work properly when they are bounced by pluggin/unpluggin the cable. |
Issue will be observed when link is flapped or cable pulled on WAN interfaces of NFX150 |
PR Number | Synopsis | Category: QFX PFE CoS |
1432078 | Shaping does not work after the reboot if "shaping-rate" is configured. |
On QFX5110, QFX5100 and EX4600 platforms, if "shaping-rate" is configured, the shaping feature might not work after a reboot. The service might be impacted as the traffic cannot be rate limited. |
PR Number | Synopsis | Category: QFX PFE L2 |
1462171 | The LLDP function might fail when a Juniper device connects to a non-Juniper one |
On EX/QFX platforms with STP disabled, the LLDP function might fail when a Juniper device connects to a non-Juniper one. In this scenario, the LLDP PDU with destination MAC 01:80:c2:00:00:00, which is one of the three reserved MAC addresses for LLDP in IEEE 802.1AB, will be ignored by Juniper LLDP process, and this causes the LLDP function failure. This issue has service impact. |
1474142 | Traffic might be affected if composite next hop is enabled |
On QFX5000 and EX4600 platforms with composite next hop enabled, traffic loss would occur when deleting leaked routes with composite next hop. |
PR Number | Synopsis | Category: QFX L3 data-plane/forwarding |
1455547 | The coredump might occur during adding/removing EVPN Type-5 routing instance |
On QFX platforms, the coredump might occur during adding/removing EVPN Type-5 routing instance. The EVPN route would be corrupted and traffic/service impact appears if hitting the issue. |
1477073 | GRE transit traffic does not forward in VRRP scenario |
On QFX5110 platforms, GRE transit traffic might be dropped when sending GRE tunnel packets with the destination MAC as VRRP MAC. It has a traffic impact. |
PR Number | Synopsis | Category: MX Layer 2 Forwarding Module |
1464778 | Type 1 ESI/AD route might not be generated locally on EVPN PE in the all-active mode |
In a scenario when the VGA on IRB is deactivated/activated/configuration commit at the same time on both PEs of a site, the type 1 ESI/AD route might not be generated locally. |
PR Number | Synopsis | Category: MX SCB software |
1461387 | REDBULL : RPT : MX2010/MX2020 - No Alarm was generated when FPC connected to master RE via backup RE/CB |
Not fixed for MX2020/MX1010 series, will fix in other releases. |
PR Number | Synopsis | Category: Border Gateway Protocol |
1442902 | The CPU utilization on rpd spins at 100% once the same external BGP route is learned in different vrf tables |
With "advertise-external" knob configured in BGP and "auto-export" knob configured in vrf, once the same external bgp route is learned in different vrf via the import policy, the CPU utilization on rpd will spin at 100% immediately. |
1466709 | BGP peers might flap if the parameter of hold-time sets small |
On all Junos platforms with BGP enabled, the hold timer is still running when the session is to processing BGP updates to peers, but the keepalive messages which BGP peer sends might be skipped. If the BGP updates in handling cannot be completed within the hold timer (e.g., manually sets the hold-time to 3s), the BGP peer flaps might be observed. |
PR Number | Synopsis | Category: MX Platform SW - FRU Management |
1463169 | The RE switchover may not be triggered when the master CB clock failure |
On the specific Junos platforms, the RE switchover may not be triggered when the master CB clock failure is detected. The master CB with faulty clock can't operate normally and this issue may cause fabric plane failure. |
PR Number | Synopsis | Category: Covers Application classification workflows apart from custo |
1454180 | Introduction of default inspection-limits to AppID to optimize CPU usage and improve resistance to evasive applications |
AppID is significantly more resistant to evasive applications. It does this by introducing default inspection-limits which can be adjusted by using the new commands 'set services application-identification inspection-limit' and 'set services application-identification global-offload-byte-limit'. |
PR Number | Synopsis | Category: Control Plane for Node Virtualization |
1451215 | Main chassisd thread at a JNS GNF could experience stalls upon GNF SNMP polling for hardware-related OIDs |
- Chassisd main thread stalls could be seen at a JNS GNF upon GNF SNMP polling for HW-related OIDs (e.g. ones from jnxBoaAnatomy MIB). - If a GNF chassisd main thread stalls are ongoing and the GNF is restarted, then a service MGD process at the BSYS could start spinning at 100% CPU. This MGD process won't terminate by itself and will be consuming 100% CPU even when the GNF is back online. |
PR Number | Synopsis | Category: dynamic dcd prs |
1470622 | Executing commit might hang up due to stuck dcd process |
When dynamic DHCP sessions are existing in the device, if multiple commits in parallel are performed, the commit might hang up. |
PR Number | Synopsis | Category: ISIS routing protocol |
1463650 | The ISIS IPv6 routes might flap when there is an unrelated commit under protocol stanza |
With multi-topology enabled in ISIS globally hierarchy level, if some ISIS interfaces don't have IPv6 address, all ISIS IPv6 routes flap when committing any change under protocol stanza (e.g. 'protocol pim traceoption'). |
PR Number | Synopsis | Category: Platform infra to support jvision |
1475036 | Memory leak leading to MPC10E line card restart |
The "sensord" daemon on MPC10E linecards leaks memory at a rapid rate. The memory leak results in total memory exhaustion. Consequentially, all control traffic transiting all PFEs on the MPC10E stalls. Shortly after this stall the MPC10E may restart. If the MPC10E restarts there will be no core dump recorded. The rate of memory leak varies depending on the number of populated optics in the MPC10E and on the number of MPCs installed in the system. Typically the MPC10E will restart in this manner after 15 days of operation. [TSB17705] |
PR Number | Synopsis | Category: Label Distribution Protocol |
1471191 | The rpd process might crash during shutdown. |
The rpd shutdown process such as clean up of scale configuration and rolling it back with LDP configured might cause rpd to crash. Rpd shutdown rarely happens during normal operation. It is widely used for testing purpose. Rpd crash may result in traffic loss. |
PR Number | Synopsis | Category: mc-ae interface |
1479012 | MC-AE interface may be shown as unknown status if adding the sub-interface as part of the VLAN on the peer MC-AE node |
If adding the sub-interface as part of the VLAN on the peer MC-AE node while its corresponding MC-AE interface is still not configured to be part of the VLAN, the status of the MC-AE interface might be shown as unknown. It might have an impact on the traffic as the colour of the MC-AE interface could not be updated correctly. |
PR Number | Synopsis | Category: MPC11 ULC interface software related issues. |
1459942 | Redbull:MPC11E: Interface flaps multiple times after an admin disable/enable at the MPC11E side, or when an optical module is plugged into MPC11E |
When an MPC11E interface is administratively disabled and then enabled or when an optical module is plugged in, during the bring up of the interface, the interface might flap more than once |
1470153 | On MPC11E, some of 10g interface states may not cleaned up correctly when performing GRES with invalid profile config |
On MPC11E, if user has invalid port profile, and performs RE Switch over, then some of the interfaces gets into invalid state. |
1471894 | Port identification via LED blinking for the 100G/40g/10G ports does not work on MPC11E |
On the MPC11E card, locating a specific 100g/40g/10g port in the card by blinking the corresponding port LED via the "request chassis port-led start/stop" does not work |
PR Number | Synopsis | Category: MPC11 ULC platform software related issues. |
1467725 | Hotswap between MPC11e and MPC9/8/6 is not supported |
On MX2020/MX2010 platforms, hotswap MPC11e with MPC9/8/6 or vice versa will result in training failures. It is recommended to power-off the chassis before swapping the cards. |
PR Number | Synopsis | Category: Fabric Manager for MX |
1436148 | Redbull-SFB3 : ZF interrupts [MAJOR] Out-of-range Dest PFE INTR for Gnt seen during MPC6/9 linecard bringup |
ZF interrupts [MAJOR] Out-of-range Dest PFE INTR for Gnt seen during MPC6/9 linecard bringup, which has no functional impact |
PR Number | Synopsis | Category: MX10K platform |
1471372 | Sudden FPC shutdown due to hardware failure or ungraceful removal of line card may cause major alarms on other FPCs in the system |
On the MX10008/MX10016 platforms, If the FPC line card gets offline due to power failure or FPC Line card is removed from the chassis without prior offline of the card, other FPC line cards in the system will report fabric failures and fabric self-ping failures. The fabric self-ping failure will invoke disable-pfe action. Once PFE is disabled due to disable-pfe action, the line card needs to get restarted to recover. |
1472660 | [resiliency] [generic_RE] Active errors counts are not increasing for I2C in SYNCE cards |
"show chassis environment cb" does not show correct temperature sensor value. All values are reported as 0. |
PR Number | Synopsis | Category: FreeBSD Kernel Infrastructure |
1454950 | EX switches might not come up properly upon reboot |
EX switches might not come up properly upon reboot due to the date not been set up |
1469400 | EX3400 might reboot because of lack of watchdog patting |
On EX3400, if watchdog pat did not happen within stipulated time and it might reboot automatically with "0x2:watchdog" as reboot reason. |
PR Number | Synopsis | Category: OSPF routing protocol |
1452118 | The TI-LFA backup path for adj-sid is broken in OSPF |
The TI-LFA (Topology-Independent Loop-Free Alternate) backup path for adj-sid is broken in OSPF where the shortest path to the node opposite the adj-sid is not the one hop path over the interface indicated by the adj-sid. |
PR Number | Synopsis | Category: MPLS Point-to-Multipoint TE |
1454987 | P2MP LSP might flap after VT interface in MVPN routing instance reconfigured |
When an interface in Multicast VPN (MVPN) routing instance is changed from virtual tunnel (VT) interface to label-switched (LSI) interface, P2MP LSP might get stuck in an incorrect state due to no tear down message created from LSP egress side. In the end, MVPN traffic will be lost. |
PR Number | Synopsis | Category: Path computation client daemon |
1472051 | The pccd core and PCEP session flaps might be seen in PCE Initiated or PCE delegated LSP scenario |
The pccd core and PCEP (Path Computation Element Protocol) session flaps might be seen when PCC (Path Computation Client) tries to send a report to PCE but the connection between PCC and PCE is not in UP state. It might also cause rpd core. This issue might happen in MBB (Make-before-break) cases in PCE provisioned/controlled LSP or doing ISSU upgrade operation. |
PR Number | Synopsis | Category: QFX PFE Class of Services |
1472223 | The shaping of COS does not work after reboot |
On EX/QFX Series platforms, the shaping of CoS does not work after reboot when the shaping rate is configured with an absolute value. The line rate of traffic is sent out and no shaping occurs. This issue has traffic or service impact. |
PR Number | Synopsis | Category: QFX L2 PFE |
1474545 | Continuous error log messages might be raised on QFX5K platforms in EVPN/VXLAN scenario |
In EVPN-VXLAN scenario, when an SP style interface is configured both with native-vlan-id and LLDP on QFX5000 platforms, continuous log messages might be observed. |
PR Number | Synopsis | Category: QFX VCCP |
1454343 | Master FPC might come up in master state again after reboot instead of backup |
In QFX5110-32Q VC with 100G VCP links, if the master switch with the lowest MAC address reboot, it might come up in the master state again instead of backup. This can have outage around ten minutes and packets loss. |
PR Number | Synopsis | Category: security-intelligence feature on SRX |
1472926 | SRX PFE memory might be used up if the security intelligence feature is configured |
On all SRX platforms, if the security intelligence feature is configured, PFE memory leak might happen while handling HTTP Uniform Resource Identifier (URI) and the memory might be used up. The memory leak size depends on the length of the HTTP URI request. The HTTP URI request length can be a few bytes to a few KB. If the average length of URI is 100 bytes, then the memory leak is 100 bytes for each request. If the available memory is consumed, the PFE has to be restarted manually. The traffic might be impacted during that time. |
PR Number | Synopsis | Category: platform related PRs on SRX branch platforms |
1474985 | The command "request system power-off" and "request system halt" may not work correctly |
The command "request system power-off" and "request system halt" might not work, it may cause a reboot instead of halting it. |
PR Number | Synopsis | Category: Stout PF fabric (SFB2) |
1461356 | Traffic might be impacted because the fabric hardening is stuck |
Fabric hardening (FH) is the process of controlling bandwidth degradation to prevent traffic black hole. When FH is processing, if SFB/SCB get failure, FH process will be stuck, which will get traffic lost. |
PR Number | Synopsis | Category: Trio LU, IX, QX, MQ chip drivers, ucode & related SW |
1449427 | Cm errors on certain MPC line cards are classified as major, which should be minor or non-fatal. |
Cm errors on certain MPC line cards are classified as major which should be minor or non-fatal. If these errors are generated, it might get projected as a bad hardware condition and therefore trigger Packet and Forwarding Engine disable action. |
PR Number | Synopsis | Category: Trio pfe bridging, learning, stp, oam, irb software |
1466602 | EVPN-VXLAN Tpye-5 tunnel might not work properly on MX platforms |
On MX platforms with EVPN-VXLAN Tpye-5 tunnel used, when the VRF of Type-5 destination IP (toward host) is different from the default VRF (the tunnel end point in the underlay), Tpye-5 tunnel might not work properly, and ip-prefix-routes are not reachable. |
PR Number | Synopsis | Category: SW PRs related to JSU support TVP platforms. |
1457304 | PID is same pre & pro installation of JSU package |
JSU Package when installed for LCMD daemon may not restart the daemon with new daemon package. Workaround: Restart LCMD daemon :- Get the LCMD process via request vmhost exec ?ps -afx |grep lcmd? Restart the process via request vmhost exec ?kill -9 from above command? |
PR Number | Synopsis | Category: PTX/QFX100002/8/16 platform software |
1464119 | FPC might restart during run time on PTX10K/QFX10K platforms |
On PTX10K/QFX10K platforms, FPC might restart if there is some corruption in BCM (Broadcom) switch (a small internal ethernet switch, instead of PFE engine) inside the FPC. It is a timing issue. The reason is that the PCIe speed configuration for BCM switch is not correct. And this issue is resolved in some FPC U-boot versions. |
PR Number | Synopsis | Category: ZT pfe infra issues |
1471554 | Redbull:MPC11E: MTU errors count captured in the show pfe statistics traffic are not matching exactly to the actual count of frames dropped. seems some incorrect cumulative value is shown |
MPC11E: MTU errors count captured in the show pfe statistics traffic are not matching exactly to the actual count of frames dropped. seems some incorrect cumulative value is shown |
PR Number | Synopsis | Category: ZT pfe firewall software |
1470629 | Certain Configuration steps will cause traffic to not get policed properly on MPC-11E interfaces |
MPC-11E interface traffic policer does not apply correctly when modifying the policer template and unbind the filter that uses that policer as a filter action in the same commit |
PR Number | Synopsis | Category: ZT pfe l3 forwarding issues |
1474160 | An MPC11 crash might occur on MX2K platform using multi-dimensional advanced scale configuration having Inline Keep Alive Sessions |
On an MX2020 platform, in a rare scenario, after loading a complex multiple dimensional configuration with scaled Inline KA sessions, an MPC11 crash might occur due to transient condition of change and add of Inline Keep alive sessions. |
Getting Up and Running with Junos
Getting Up and Running with Junos Security Alerts and Vulnerabilities Product Alerts and Software Release Notices Problem Report (PR) Search Tool EOL Notices and Bulletins JTAC User Guide Customer Care User Guide Pathfinder SRX High Availability Configurator SRX VPN Configurator Training Courses and Videos End User Licence Agreement Global Search