Search our Knowledge Base sites to find answers to your questions.
Ask All Knowledge Base Sites All Knowledge Base Sites JunosE Defect (KA)Knowledge BaseSecurity AdvisoriesTechnical BulletinsTechnotes Sign in to display secure content and recently viewed articles16.1R7-S7: Software Release Notification for JUNOS Software Version 16.1R7-S7
NOTE
PR1463859 introduces a software defect that causes a 10GE interface to flap continuously when configured with the WAN-PHY framing with the default "hold-down" timer (0). Once you upgrade a router to an affected software release, the interface may flap continuously. This is not applicable to an interface with the default framing - LAN-PHY. [TSB17782]
PR Number | Synopsis | Category: EX2300/3400 CP |
---|---|---|
1192363 | On Ex3400 and EX2300 switches, when client is authenticated in Dynamic/Server-fail/Server-reject/Guest vlan multiple supplicant mode, ping failure can be seen between client and switch. |
On Ex3400 and EX2300 switches,when client is authenticated in Dynamic/Server-fail/Server-reject/Guest vlan multiple supplicant mode, ping failure can be seen between client and switch. |
PR Number | Synopsis | Category: Accounting Profile |
1452363 | The pfed might crash and not be able to come up on the PTX or TVP platforms |
The flow label statistics are retrieved periodically by pfed for PTX or TVP platforms, if the statistics reply becomes very big number, the pfed might crash hence affecting traffic. |
1458008 | MX: syslog errors @ pfed: rtslib: ERROR received async message with no handler: 28 |
An MX router configured for Subscriber Management, and "chassis network-services enhanced-ip", may see log messages similar to Jan 1 01:00:00 MXrouter_RE0 pfed: rtslib: ERROR received async message with no handler: 28 |
1458143 | PFED fails to retrieve statistics from PFE for (ESSM) subscribers. Error message: libstats_error: interim-or-baseline-stats-not-found |
In some occasions upon FPC reboot, the pfed database might not get updated with the correct location_id for some physical interfaces (IFDs). This results in an error when the timeout for a ESSM subscriber connected to such an interface reaches it's limit and the pfed daemon tries to collect the statistics for the subscriber in PFE based on this wrong location_id. The error "essmd[xxxx]: is_stats_error_retryable: ifl name: ge-x/x/x.xxx, libstats_error: interim-or-baseline-stats-not-found" will be logged in the messages log. |
PR Number | Synopsis | Category: MPC Fusion SW |
1463859 | The MPC2E-NG/MPC3E-NG card with specific MIC might crash after a high rate of interface flaps |
If any MIC of MIC-3D-2XGE-XFP / MIC-3D-4XGE-XFP / MIC-3D-20GE-SFP-E / MIC-3D-20GE-SFP-EH / MIC-MACSEC-20GE is installed in MPC2E-NG/MPC3E-NG card, the Microkernel (uKern) might hog for CPU on Packet Forwarding Engine (PFE) when there is a high rate of interface flaps (~30/40 flaps per second). This will eventually trigger the MPC2E-NG/MPC3E-NG card crash with an NGMPC core file. Normally the excessive interface flapping won't happen frequently in real world and it may be caused due to external environment. This fix will reduce the impact and prevent the uKern hog when having such conditions. |
PR Number | Synopsis | Category: Border Gateway Protocol |
1366823 | Ukern memory leak and core crash in BGP environment |
Ukern memory leak and fpc core crash might be happened when device configured link-node protection with labeled-bgp. |
1389379 | FPC might crash when BGP multipath is configured with protection |
When running with Border Gateway Protocol (BGP) multipath with protection configured, it is possible to encounter a situation where nexthops references are not properly decremented, thus causing the system to hold onto nexthops when they should be freed. This leads to a memory hog situation which eventually results in a Flexible PIC Concentrator (FPC) crash. |
1454198 | The rpd scheduler slip for BGP GR might be up to 120s after the peer goes down |
In BGP GR (graceful-restart) scenario (graceful-restart is configured for BGP or GR-helper mode is enabled by default), when high-scale routes get learnt from one peer, the rpd scheduler slip might be up to 120s after that BGP peer flaps. |
1454951 | The rpd process might crash when multipath is in use |
If multipath is enabled, in some certain conditions, The rpd process might crash while secondary route resolution is running. |
1487691 | RPD's bgpio thread goes into high CPU utilization when the outgoing BGP updates queue is full |
RPD goes into high CPU utilization causing slow BGP network convergence on a large scale setup. The high CPU utilization of the BGP IO thread (bgpio) happens when the outgoing BGP update queue is full. The typical situation is a BGP Route-Reflector (RR) sending a large number of BGP updates (900K routes) to a large number of slow peers (more than 200 peers). This issue is the side-effect of PR1351639. (See also https://kb.juniper.net/TSB17725) |
PR Number | Synopsis | Category: MX Platform SW - System Buses |
1299594 | CHASSISD_I2CS_READBACK_ERROR: Readback error from I2C slave for FPC 0 ([0x10, 0x3a] -> 0x0) |
Chassisd may report readback error for MPC 3D 16x10G FPCs when it?s trying to access 0x3a register. However, it?s an invalid register for this type of FPC so error got reported.The log itself is non-impacting and can be safely ignored. |
PR Number | Synopsis | Category: dhcpd daemon |
1457949 | Show subscriber extensive incorrectly displays DNS (domain-name-server) address provided to DHCP clients |
Show subscriber extensive incorrectly displays DNS (domain-name-server) address provided to DHCP clients |
PR Number | Synopsis | Category: JUNOS Dynamic Profile Configuration Infrastructure |
1379482 | The subinfo process might crash with core file if flapping all the subscribers |
On MX platforms with large scaled number of subscribers login, if flapping all the subscribers and executing the command "show subscriber summary port", the subinfo process might crash. |
PR Number | Synopsis | Category: dynamic dcd prs |
1470622 | Executing commit might hang up due to stuck dcd process |
When dynamic DHCP sessions are existing in the device, if multiple commits in parallel are performed, the commit might hang up. |
PR Number | Synopsis | Category: Ethernet OAM (LFM) |
1253542 | In a VPLS multihoming scenario, the CFM packets can be forwarded over backup, standby, non-designated, or CCC-down link, which might cause the traffic to be endlessly looped |
In a VPLS multihoming scenario, the CFM packets are forwarded over the standby PE device link, resulting in duplicate packets or a loop between the active and standby link. |
PR Number | Synopsis | Category: Express PFE L2 fwding Features |
1399369 | CPU hog may be observed on PTX/QFX10000 Series platform |
On PTX/QFX10000 series platform, CPU hog on PFC may be observed if the adaptive feature is enabled to load-balance for an AE interface. |
PR Number | Synopsis | Category: Express PFE L3 Multicast |
1389569 | BFD flaps are seen on PTX or QFX10K platforms with inline BFD |
With inline-BFD configured on the PTX or QFX10000 platforms, BFD sessions might flap continuously. |
PR Number | Synopsis | Category: Kernel software for AE/AS/Container |
1440033 | Traffic loss is observed on newly added interfaces in AE on "MX and EX platforms" |
On MX and EX series devices that support the "enhanced-ip" feature and when the new interface is added to aggregated ethernet (ae), output traffic is observed as 0 on the existing member links. This is being observed due to software issues as wrong weights are being set for existing child interfaces in the AE bundle. |
PR Number | Synopsis | Category: Label Distribution Protocol |
1460292 | High CPU usage and rpd coredump might be observed if "ldp track-igp-metric" is configured and IGP metric is changed |
If "protocols ldp track-igp-metric" is configured, metric change of IGP route might cause high CPU usage and rpd coredump on the device. |
PR Number | Synopsis | Category: MQTT protocol, Mosquitto Broker and Client API |
1140087 | Mosquitto log file management enhancement |
Before 16.2R1, Mosquitto daemon (3rd party s/w) does not have log management features. It will write logs named with "mqtt_" under /var/log/ until the disk is full which is a problem. After 16.2R1, Junos adds the log management features to the Mosquitto logs. The log size can be maximum 4.0 Mbytes and it keeps 10 archives. From 18.4 onwards, Junos will not use such daemon so these logs won't be generated at all. |
PR Number | Synopsis | Category: FreeBSD Kernel Infrastructure |
1146891 | EX4300-48MP: 'set system ports console log-out-on-disconnect' does not work |
'set system ports console log-out-on-disconnect' does not work |
PR Number | Synopsis | Category: "ifstate" infrastructure |
1404507 | The VMCore might be seen when there is an interface deletion |
In a very rare situation, The VMCore might be seen when there is an interface deletion/addition. |
PR Number | Synopsis | Category: PTX Broadway based PFE MPLS-LSPs RSVP VPNs tcc ccc software |
1484255 | FPC might crash when dealing with invalid next-hops |
On PTX3000/PTX5000 platform with some specific FPCs, if the weights of links are set to an invalid value on an AE bundle interface or unilist (an unilist next-hop composed of several unicast next-hops), the FPC crash might be observed. It is a rare issue and the FPC will try to reload to resolve this problem. Traffic loss might be seen before the FPC completes the reload period. |
PR Number | Synopsis | Category: RPD policy options |
1357802 | Configuration commit operation after policy change causes rpd crash |
The rpd might crash during policy configuration changes. |
PR Number | Synopsis | Category: SNMP Infrastructure (snmpd, mib2d) |
1350826 | SNMP Traps not being sent by the new master RE after RE mastership switchover |
Sometimes, the trap-source-address bind is getting delayed because the platform does not attach the respective IP to any of the interfaces on the router. But since trap is generated at the start before any configured trap source-address is not yet bound properly, this trap is not added into the throttle/destination trap queues. |
1392616 | The snmpd process might crash and cause a core dump |
The snmpd process leaks memory in the SNMPv3 query path and crashes. The issue is caused by a memory leak when the request PDU is dropped by SNMP when the snmp filter-duplicates configuration is enabled. Each request PDU has a structure pointer for the SNMPv3 security details. This is allocated when the PDU is created or cloned. But while dropping the duplicate requests, the corresponding structure is not freed, which causes the memory leak. |
1413352 | The SNMP query might not get data in scaled Layer 2 circuits environment. |
When a large-scale AE interfaces are configured with a large-scale l2circuits, if executing snmpwalk on interface OID's, the query may time out and the data could not be retrieved. When the issue occurs, below error could be observed. user@router> show snmp mib walk 1.3.6.1.2.1.2.2 ... ifInOctets.70781 = 75155380 Request failed: General error user@router> show snmp mib walk ifHCInOctets ifHCInOctets.831 = 340482960268874 Request failed: General error It is to be noted that all general errors are not an issue. If there are interface flaps and churns in the system during which snmp query happens on the same interface which is flapping, then general error is the way to report it because stats cannot be fetched during the churn/flap duration. |
PR Number | Synopsis | Category: MPC7/8/9 Interface Issues |
1463015 | An interface might get stuck in down state on certain MX platforms |
The interfaces on certain MX platforms might get stuck in a down state, if the remote interface sends invalid code to the local interface. Link might not come up even after the remote peer has begun sending a good signal. |
PR Number | Synopsis | Category: Stout PF fabric (SFB2) |
1461356 | Traffic might be impacted because the fabric hardening is stuck |
Fabric hardening (FH) is the process of controlling bandwidth degradation to prevent traffic black hole. When FH is processing, if SFB/SCB get failure, FH process will be stuck, which will get traffic lost. |
PR Number | Synopsis | Category: UI Infrastructure - mgd, DAX API, DDL/ODL |
1415042 | The user might not enter configure mode due to mgd is in lockf status |
If "commit confirmed " is executed, then issuing another "commit" or "commit confirmed " after around the minutes, in race condition, a rollback might be hit. At last, it may cause the mgd process to enter and to stay in lockf status. Thus, the user might not enter configure mode anymore. |
Getting Up and Running with Junos
Getting Up and Running with Junos Security Alerts and Vulnerabilities Product Alerts and Software Release Notices Problem Report (PR) Search Tool EOL Notices and Bulletins JTAC User Guide Customer Care User Guide Pathfinder SRX High Availability Configurator SRX VPN Configurator Training Courses and Videos End User Licence Agreement Global Search