PR Number |
Synopsis |
Category: PFE SW evo-pfemand,packet-io on BRCM platforms running EVO |
1513109 |
servicability scheduler on LAG with 2 member links doesn't work
Product-Group=evo |
QFX running Junos Evolved's "scheduler" on LAG interfaces with 2 member links does not work properly |
1521531 |
Scheduling variance will be seen when queue 3 & 4 congested on QFX5220
Product-Group=evo |
QFX5220 - Class of Service - Scheduling transmit rate & shaping rate variance will be seen on QFX5220 when Queue 3 & Queue 4 congested along with other queues. |
PR Number |
Synopsis |
Category: management ethernet related issues - mgmt-ethd daemon |
1458228 |
The aggregated Ethernet LACP Distributed Mode - "show ppm adjacencies" does not show FPC slot number in Distribution address
Product-Group=evo |
"show ppm adjacencies" in Junos Evolved show an internal IP address instead of FPC slot number in the Distribution address |
PR Number |
Synopsis |
Category: System Management High availability |
1519364 |
GRES: show system switchover is not showing the correct state
Product-Group=evo |
There is a delay enforced between back to back switchover. This is 360 seconds unless overridden by platform specific values. So, if the last switchover happened within the last 360 seconds, then it will give this error: "Not ready for mastership switch, try after x seconds?. The "show system switchover" CLI output might show "Switchover Status: Ready". But this field indicates the ready status of all applications on backup RE. This does not consider the back-to-back switchover delay. |
PR Number |
Synopsis |
Category: mgd, ddl, odl infra issues |
1511303 |
< data> tag not found in xml output generated by rli16039combination_filter_sd.xml.
Product-Group=evo |
Eventd reads the hostname from /etc/hostname file and updates the same in all syslog files. During bootup time /etc/hostname were not updated by mgd and eventd reads the default hostname. The issue got fixed in PR 1511303 by mgd folks in recent builds. This doesn't impact the functionality and this is a high risk to backport the change(AT#82, AT#87, and AT#90 ) As a workaround, Kindly restart the relay event to avoid this issue. |
PR Number |
Synopsis |
Category: Express PFE CoS Features |
1478811 |
[cos] [scheduler] scapa:scheduler with all queues oversunscribed, max latency is different on different queues - 21ms ~ 29ms
Product-Group=evo |
CoS scheduler: With all queues oversubscribed, maximum latency varies among queues (21ms to 29 ms) |
1485478 |
In strict-priority mode, with any form of rate-limiter/shaper configured, it might create some accuracy gaps in the scheduler across queues.
Product-Group=evo |
BGP started creating route pointing to List NH having INDIRECT members inside after comcast N+1 feature. But resolver treats LIST NH as a leaf node and does not do loop detection inside List NH members (Day 1 behavior). This causes wedges in Packet Forwarding Engine as loop detection does not happen. |
1501083 |
PTX10008 EVO: Tail drops (VOQ drops) are consistently seen on a High priority queue (AF4) with "shared" buffer configs
Product-Group=evo |
A PTX10008 system running Junos EVO software with "shared" buffer configuration may see Tail drops - aka VOQ drops - on the high priority queue (AF4). This happens when the number of packet flows is too low to properly load balance traffics over member links of AE interface bundles. |
1506855 |
Shapers applied on Interface Output Queues, either through the transmit-rate "exact" or "rate-limit" knob may not sometimes draw the expected output scheduler accuracy.
Product-Group=evo |
Shapers applied on Interface Output Queues, either through the transmit-rate "exact" or "rate-limit" knob may not sometimes draw the expected output scheduler accuracy. |
1523066 |
With traffic running, if the FPC which is connected to traffic generator is rebooted, it might lead to stuck traffic scenario on certain ports post resumption.
Product-Group=evo |
With traffic running, if the FPC which is connected to traffic generator is rebooted, it might lead to stuck traffic scenario on certain ports post resumption. |
PR Number |
Synopsis |
Category: Express PFE FW Features |
1499294 |
On a QFX5220 :: show firewall cli shows error error: communication failure with /re0/evo-pfemand/ when unique filter is applied over all physical interfaces.
Product-Group=evo |
show firewall cli shows error error: communication failure with /re0/evo-pfemand/ when unique filter is applied over all physical interfaces. |
PR Number |
Synopsis |
Category: Express PFE MPLS Features |
1472908 |
Traffic loss of up to 400 ms can be seen in MPLS FRR scenario
Product-Group=evo |
Traffic loss of upto 400 ms is seen during MPLS FRR test with following scale: 600K IPv4 routes 40K IPv6 routes 19K Transit LSPs 1.6K ingress LSPs 10K BGP LU. |
1517870 |
MPLS ping will not work RSVP LSP with UHP configured
Product-Group=evo |
MPLS ping will not work RSVP LSP with UHP configured |
PR Number |
Synopsis |
Category: Path computation client daemon |
1481462 |
[northstar_pccd] [tag_rro_mismatch] After interface flap,RRO mismatch between pcep and mpls(p2mp)
Product-Group=evo |
There is a minor data mismatch in RRO between PCE and PCC. |
PR Number |
Synopsis |
Category: Resource Reservation Protocol |
1518968 |
After graceful switchover, ingress RSVP sessions go down and take up to 5 minutes to come up.
Product-Group=evo |
After graceful switchover, ingress RSVP sessions in new master go down and take up to 5 minutes to come up. |
PR Number |
Synopsis |
Category: PTX10K platform specific fabric PRs |
1511918 |
fabric_down_condition_on_pfe errors not cleared when fpc is offlined after fabricHub app restart
Product-Group=evo |
fabric_down_condition_on_pfe errors not cleared when fpc is offlined after fabricHub app restart |
1514668 |
Sib fault errors and alarms are not cleared after sib is recovered following fabspoked-fchip abrupt kill and restart
Product-Group=evo |
Sib fault errors and alarms may not get cleared after sib is recovered following fabspoked-fchip process' abrupt kill and restart. |
1515790 |
For fabspoked-pfe, 'Restart Supported' and 'Restart Node' flags are incorrect in the output of 'show system applications app'
Product-Group=evo |
For fabspoked-pfe, 'Restart Supported' and 'Restart Node' flags are incorrect in the output of 'show system applications app fabspoked-pfe detail'. Show command shows that app can be restarted without needing node reboot, but restarting the app leads to node reboot. |
PR Number |
Synopsis |
Category: PTX10K RE EVO Issues |
1503269 |
[generic_evo] - PTX1008: RCB: Switchover Status is not reflecting as expected at "show system switchover" in new backup post performing mastership switchover
Product-Group=evo |
According to the current implementation, to display switchover status using the show system switchover command on backup, only the readiness of configuration database, object database and applications: ready state are considered. It does not check for the output of the request chassis routing-engine master switch check command. As a result, in some of the cases the output of both the commands could be different for 'switchover readiness' for a short duration of time. This is a day-1 behavior in Junos OS Evolved.
|